3-4
XZAC4219-03
3.2.2
INSTALLATION OF THE MACHINE
Position the machine where it is to be used, checking compliance with the indications provided in paragraph
3.1.
Make sure that the voltage indicated on the dataplate matches that of the local power supply. Connect the
mains cable and switch on the printer.
Check power-on through the mechanism reset phase and lighting up of the ON led on the console.
If other Leds apart from the ON led remain on, consult paragraph 2.2.3 "Error messages ".
3.3
OFF-LINE TEST
A print test can be carried out to check functioning of the printer before connecting it to the system.
3.3.1
ACTIVATION AND DE-ACTIVATION OF THE PRINT TEST
To activate the test, proceed as follows:
•
Switch off the printer.
•
Switch on the printer holding down the STATION 2/EJECT key of the console.
•
At the end of the initialization phase, insert an A4 format sheet in the introduction slot until the paper
alignment photosensor is activated.
The machine automatically feeds the sheet and prints the test. The sheet is ejected automatically at the end of
the test. To repeat printing, simply insert a new sheet.
To de-activate print test mode, switch off the printer.