XZAC4219-03 Service
Manual
8-15
8.14
POSITIONING OF GROUP ON THE HORIZONTAL MAGNETIC/MICR STRUCTURE
MACHINE STATUS:
Insignificant.
CONDITIONS TO BE CHECKED:
Co-planarity between the closing flap of the magnetic unit and the paper conveyor of the slot.
PROCEDURE:
Position the slots (1) in the half cut-outs (2) present on the sides of the machine.
Draw up the lock-screws slightly (3).
Push up the structure of the magnetic unit until it is in contact both to the right and left (against the paper
conveyor).
Torque the lock-screws to 8 Kgcm.
Figure 8-14
2
1
3