XZAC4219-05
Service Manual
5-9
ERROR
Magnetic Reset
No timeout
Horizontal magnetic or MICR module error on reset sequence
Replace the horizontal magnetic or MICR interface card. See the
section
“Horizontal magnetic/MICR disassembly/reassembly” on
page 7 - 28.
ERROR
Motor Carriage
No timeout
Motor carriage reset error
See the section
“Faults with document handling” on page 5 - 19
.
Scanner error
FPGA LOAD
No timeout
Error on programming FPGA scanner.
•
Perform calibration of the scanner. See the section
“Calibrating the scanner” on page 4 - 28
•
Replace the motherboard. See the section
“Disassembling/
reassembling the motherboard (printers with scanner)” on
page 7 - 21.
Scanner error
AFE TALK
No timeout
Analog Front End seria comunication error
•
Perform calibration of the scanner. See the section
“Calibrating the scanner” on page 4 - 28
•
Replace the CIS. See the sections:
“CIS assy (upper scanner)
disassembly/reassembly” on page 7 - 33
and
“CIS assy (lower
scanner) disassembly/reassembly” on page 7 - 34
.
Scanner error
STATIC RAM
No timeout
Static RAM error scanner.
Replace the motherboard. See the section
“Disassembling/
reassembling the motherboard (printers with scanner)” on page 7 -
21
.
Scanner error
DYNAMIC RAM
No timeout
Dynamic RAM error scanner.
Replace the motherboard. See the section
“Disassembling/
reassembling the motherboard (printers with scanner)” on page 7 -
21
.
Make SCANNER
Calibration
No timeout
Adjustment scanner area corrupted or not valid.
Perform the scanner calibration.
•
Press any key on the console to display the next anomaly,
when necessary.
•
Perform calibration of the scanner. See the section
“Calibrating the scanner” on page 4 - 28
.
MESSAGE
TIME OUT
DESCRIPTION
Содержание PR2 PLUS
Страница 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Страница 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Страница 10: ...Index x Page left intentionally blank...
Страница 81: ...XZAC4219 05 Service Manual 4 27 Figure 4 5 Printing calibration values when verifying Jitter Magnetic test...
Страница 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Страница 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Страница 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Страница 172: ......