5-6
Service Manual
XZAC4219-05
O
X
-
X
-
FPGA scanner
error
•
Perform calibration of the
scanner. See the section
“Calibrating the scanner” on
page 4 - 28.
•
Replace the motherboard. See
the section
Disassembling/
reassembling the motherboard
(printers with scanner).
O
X
O
X
X
HW Setup - On
the display (if
present) appears
the message
«
WARNING
Setup
Hardware
».
Inconsistency of
calibration values
(photosensors,
alignments etc).
All the calibration
values are
initialised with
their default
values.
•
Press any key on the console to
display the next anomaly, when
necessary.
•
Perform all the printer
calibrations. See the section
“PROGRAMMING AND
CALIBRATION” on page 4 - 1.
•
Replace the motherboard. See
the section
Disassembling/
reassembling the motherboard
(printers with scanner)
or
Disassembling/reassembling
the motherboard (printers with
serial number 8.xxx.xxx and
1.xxx.xxx).
O
X
X
-
-
Carriage motor
See the section
“Faults during
writing of the document” on page 5 -
17.
O
X
X
-
X
Scanner STATIC
RAM error
Replace the motherboard. See the
section
Disassembling/
reassembling the motherboard
(printers with scanner).
O
X
X
X
-
Scanner
DYNAMIC RAM
error
Replace the motherboard. See the
section
Disassembling/
reassembling the motherboard
(printers with scanner).
O
X
-
X
X
Perform the
scanner
calibration - On
the display (if
present) the
message
appears «
Make
SCANNER
Calibration
».
•
Press any key on the console to
display the next anomaly, when
necessary.
•
Perform calibration of the
scanner. See the section
“Calibrating the scanner” on
page 4 - 28.
O
O
O
-
O
PTC power unit
not working
Replace the power unit. See the
section
“Power supply unit
disassembly/reassembly” on page 7
- 26
.
Console LED
Anomalies
Possible solution
ON
Ready
Station1
Local
Station 2
Содержание PR2 PLUS
Страница 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Страница 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Страница 10: ...Index x Page left intentionally blank...
Страница 81: ...XZAC4219 05 Service Manual 4 27 Figure 4 5 Printing calibration values when verifying Jitter Magnetic test...
Страница 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Страница 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Страница 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Страница 172: ......