XZAC4219-05
Service Manual
4-21
Printing photosensor calibration values
Bi-directional printing speeds up the writing of the printer, but it could reduce printing quality if a misalignment
occurs between the lines written from left to right and vice-versa. To eliminate this defect, you can optimise the
alignment of bi-directional printing through calibration.
Calibration must be performed for each of the following printing modes:
•
Very High Speed Draft, High Speed Draft
•
Draft
•
Near Letter quality, Letter quality
To calibrate the alignments, proceed as follows.
1.
Open the printer cover.
2.
Power on the printer, with the cover open, keeping the three
console keys pressed.
3.
Wait for the acoustic signal that indicates access to the
calibration and adjustment procedure, then close the cover.
4.
Press the
STATION1
button.
5.
Press the
STATION2
button.
6.
Press the
STATION1
and
STATION2
keys simultaneously.
For all the printing modes, the default values theoretically
near to the correct ones will be saved.
7.
Insert an A4 sheet in the front slot to check print alignment
status.
8.
Press the
STATION1
and/or
STATION2
keys to calibrate the
alignments.
•
By pressing the
STATION1
key you can anticipate start of
printing.
•
By pressing the
STATION2
key you can delay the start of
printing.
9.
Repeat points 7 and 8 until calibration has been completed.
10.
Press the
LOCAL
button twice to save the alignment value
permanently for the current mode and to move automatically
to the next calibration.
11.
Carry out the calibration for the printing modes required.
12.
To terminate the calibration, switch off the printer.
NOTE:
mode and spacing changes occur automatically.
+
-
Содержание PR2 PLUS
Страница 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Страница 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Страница 10: ...Index x Page left intentionally blank...
Страница 81: ...XZAC4219 05 Service Manual 4 27 Figure 4 5 Printing calibration values when verifying Jitter Magnetic test...
Страница 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Страница 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Страница 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Страница 172: ......