XZAC4219-05
Service Manual
7-31
Roller assy (upper scanner) disassembly/reassembly
1.
Remove the casing. See the section
“Casing disassembly/reassembly” on page 7 - 4
.
2.
Remove the upper mechanical assy. See the section
“Upper mechanical assy disassembly/reassembly” on
page 7 - 11
.
3.
Back off the four lock-screws
(2)
of the roller assy
(1)
.
4.
Remove the roller assy
(1)
lifting this as indicated in the figure and taking care not to mislay the transmission
shaft
(3)
.
Figure 7 - 42
Disassembling the roller assy (upper scanner)
5.
Remove the clamps
(4)
and recover the clips
(5)
.
Figure 7 - 43
Clamps fastening roller unit
1
2
3
2
4
5
4