XZAC4219-05
Service Manual
6-9
Adjusting the roller gears
•
MACHINE STATUS
–
Printer switched off and without casing.
–
Upper part of the mechanism closed.
•
CONDITIONS TO BE CHECKED
Gearing between the sprocket wheels
(1)
and
(2)
with a maximum radial play between the teeth of 0.2 mm.
Check for full rotation of wheels. Adjust the two couplings present on the right side of the printer.
•
PROCEDURE
Work on the bushing blocking screws
(3)
, tightening with a torque of 6 +0.5 Kgcm.
Figure 6 - 8
Adjusting the roller gears
NOTE:
make this adjustment on both the gear pairs present on printer.
•
1
2
3
< 0,2 mm