XZAC4219-05
Service Manual
5-17
Faults during writing of the document
Fault
Possible cause
Solution
The mac
h
ine
does
not sw
itch on
The mac
h
ine
does not
connect with the
s
ystem
The self-test indicates a
fault o
n the
Motherboard
The self-text indicates an
e
rror
i
n
the me
ch
ani
c
s
The mac
h
ine
does
not sw
itch on
The mac
h
ine
does not
connect with the
s
ystem
X
X
Ribbon cartridge
missing
Insert a ribbon cartridge. See
“Installing
the ribbon cartridge” on page 2 - 6
X
Ribbon to be
replaced (out)
Replace the ribbon cartridge. See
“REPLACING THE RIBBON
CARTRIDGE” on page 3 - 8
X
X
X
Ribbon cartridge not
inserted correctly
Check how the ribbon cartridge is
installed.
X
X
Irregular movement
of the carriage
Check the carriage. See
“Replacement
and adjustment of belt for carriage
movement” on page 6 - 15
X
X
X
X
Closing levers open
Lower the lever for closure.
X
X
Printhead fault
Replace the printhead. See
“Printhead
disassembly/reassembly” on page 7 - 10
X
X
X
Paper photosensor
fault
1
Carry out the calibration procedure.
See
“CALIBRATING THE
PHOTOSENSORS” on page 4 - 18
2
Clean and, if necessary, replace the
defective photosensor. See
“PROCEDURE FOR CLEANING /
REPLACING THE PHOTOSENSORS”
on page 6 - 2
X
X
X
X
Printhead flat cable
fault
Replace the flat cable. See the section
“Printhead flat cable disassembly/
reassembly” on page 7 - 8
X
X
Transport motor fault
Replace the transport motor. See
“Services motor disassembly/reassembly”
on page 7 - 14
X
X
Motherboard fault
Replace the motherboard. See
“Disassembling/reassembling the
motherboard (printers with scanner)” on
page 7 - 21
or
“Disassembling/
reassembling the motherboard (printers
with serial number 8.xxx.xxx and
1.xxx.xxx)” on page 7 - 23
X
X
X
X
Adjustment of needle
roller incorrect
See
“Adjusting the roller gears” on page 6
- 9
Содержание PR2 PLUS
Страница 1: ...Printer PR2 PLUS Code XZAC4219 05 SERVICE MANUAL...
Страница 4: ...IV Service Manual XZAC4219 05 Page left intentionally blank...
Страница 10: ...Index x Page left intentionally blank...
Страница 81: ...XZAC4219 05 Service Manual 4 27 Figure 4 5 Printing calibration values when verifying Jitter Magnetic test...
Страница 83: ...XZAC4219 05 Service Manual 4 29 Figure 4 6 Scanner calibration parameters...
Страница 84: ...4 30 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 120: ...6 16 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 127: ...XZAC4219 05 Service Manual 7 7 Figure 7 8 Removing the mechanical assembly unit 2 3...
Страница 158: ...7 38 Service Manual XZAC4219 05 Page left intentionally blank...
Страница 170: ...A 8 Service Manual XZA4219 05 Page left intentionally blank...
Страница 172: ......