Field Service Ver. 1.0 Feb. 2007
9. Malfunction code
19
PK-512/513
T
roubleshooting
9.
Malfunction code
9.1
Trouble code
• The machine’s CPU performs a self-diagnostics function that, on detecting a malfunction,
gives the corresponding malfunction code and maintenance call mark on the touch
panel.
9.2
Solution
9.2.1
C1127: Punch kit movement motor drive failure
Code
Description
Detection timing
Trouble isolation
compliant unit
Rank
C1127
Punch kit movement
motor drive failure
• The after punch shift home sensor
(PS303) is not turned ON after a lapse of
a given time after the punch shift motor
(M302) is turned ON.
Punch
B
Relevant electrical parts
Punch shift motor (M302)
Punch shift home sensor (PS303)
Punch drive board (PDB)
FNS control board (FSCB)
Step
Action
WIRING DIAGRAM
Control signal
Location
(Electrical
component)
1
Check the M302 connector for proper
connection and correct as necessary.
—
—
2
Check M302 for proper drive coupling
and correct as necessary.
—
—
3
M302 operation check
PDB CN44PDB-1 to 6
PK-511/512/513
C-5
4
PS303 I/O, sensor check
PDB CN47PDB-2 (ON)
PK-511/512/513
C-5
5
Change PDB
—
—
6
Change FSCB
—
—
Y108421-6 Service Manual