
Y103920-3
Service Manual
84
•
OPTION Connector Pin Assignment
(To Option Board [Network or RS232C])
* O
I
C
: Out
: In
: Common
Pin No.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
I/O*
C
C
O
I/O
I/O
I/O
O
O
I/O
I/O
I
O
O
I/O
I/O
C
C
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I
O
C
C
O
Signal
SG
SG
PPGNT0-N
PPDVSL-N
PPTRDY-N
PPFRM-N
NC
NC
NC
OPSCC_RXD
OPSCC_DSR
PPC_BE3
PPC_BE1
PRINT0-N
PERIWR-N
NICFROM_CS
SDT22
SDT20
SG
SG
SDT18
SDT16
SDT25
SDT27
SDT29
SDT31
SDT9
SDT11
SDT13
SDT15
SDT6
SDT4
SDT2
SDT0
OPNIC-N
RESET-N
NC
SG
SG
+5V
Function
Ground
Ground
Bus Grant (PCI)
Device select (PCI)
Target Ready (PCI)
Frame (PCI)
N.C.
N.C.
N.C.
RXD (RS232C)
DSR (RS232C)
Command/Byte Enable 3 (PCI)
Command/Byte Enable 1 (PCI)
Interrupt (PCI)
FlashROM Write Enable
FlashROM Chip Select
AD Bus 22
AD Bus 20
Ground
Ground
AD Bus 18
AD Bus 16
AD Bus 25
AD Bus 27
AD Bus 29
AD Bus 31
AD Bus 9
AD Bus 11
AD Bus 13
AD Bus 15
AD Bus 6
AD Bus 4
AD Bus 2
AD Bus 0
NIC Detect
Reset
N.C.
Ground
Ground
+5V
Pin No.
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
I/O*
C
C
I/O
I/O
I/O
I/O
I/O
I
I
O
I/O
I/O
I
O
I/O
I/O
C
C
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I
I
C
C
O
O
Signal
SG
SG
PPPERR-N
PPSERR-N
PPSTOP-N
PPIRDY-N
PPPAR
NC
NC
OPSCC_TXD
OPSCC_DTR
PPCLK0
PPC_BE2
PPC_BE0
PPREQ0-N
PERIRD-N
SDT23
SDT21
SG
SG
SDT19
SDT17
SDT24
SDT26
SDT28
SDT30
SDT8
SDT10
SDT12
SDT14
SDT7
SDT5
SDT6
SDT1
OPNICSW-N
OPSCC-N
SG
SG
+5V
+5V
Function
Ground
Ground
Parity Error (PCI)
System Error (PCI)
Stop (PCI)
Initiator Ready
Parity (PCI)
N.C.
N.C.
TXD (RS232C)
DTR (RS232C)
Clock (PCI)
Command/Byte Enable 2 (PCI)
Command/Byte Enable 0 (PCI)
Bus Request (PCI)
FlashROM Read Enable
AD Bus 23
AD Bus 21
Ground
Ground
AD Bus 19
AD Bus 17
AD Bus 24
AD Bus 26
AD Bus 28
AD Bus 30
AD Bus 8
AD Bus 10
AD Bus 12
AD Bus 14
AD Bus 7
AD Bus 5
AD Bus 3
AD Bus 1
NIC Push Switch
RS232C Detect
Ground
Ground
+5V
+5V
01
03
05
07
09
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
02
04
06
08
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
•
FAN Connector Pin Assignment
(To Fan)
1
2
3
1
2
3
O
C
I
Signal
Function
FANPOW
SG
FANALM-P
Power Supply for Fan driving
Ground
Fan Alarm
PIN NO.
I/O*
* I: In
O: Out
C: Common
Содержание PG L22 Special
Страница 1: ...PG L22 Special Printer SERVICE MANUAL Code Y103920 3...
Страница 18: ...Y103920 3 Service Manual 18 Upper cover unit Figure 2 2 Upper cover...
Страница 75: ...Y103920 3 Service Manual 75 Figure 5 5 Contact High voltage sensor board Contact plate for transfer roller...
Страница 136: ...Y103920 3 Service Manual 136 6 PARTS LIST Figure 6 1 Multi Purpose Feeder 9 5 7 6 4 1 2 3 8...
Страница 137: ...Y103920 3 Service Manual 137 Table 6 1 Multi Purpose Feeder...
Страница 150: ...Y103920 3 Service Manual 150 Figure 6 1 High Capacity Second Paper Feeder 1 2 4 3 5 6 6 PARTS LIST...
Страница 151: ...Y103920 3 Service Manual 151 Table 6 1 High Capacity Paper Feeder...
Страница 153: ...Y103920 3 Service Manual 153 SECTION1 CABINET CASSETTE ASSEMBLY 5 6 3 2 4 7 8 28 28 1 29 29 i i...
Страница 164: ......
Страница 165: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 12 2004 1ST EDITION 165 Y103920 3...