13. SERVICE MODE
Field Service Ver. 1.1 May 2011
176
ADJUSTMENT
/ SETTING
13.15 CS REMOTE CARE
13.15.1
OUTLINES
• CS Remote Care enables the machine and the computer at CS Remote Care center to
exchange data through network in order to control the machine.
• CS Remote Care enables the machine to call the computer at the center when trouble
occurs. It also enables the computer at the center to contact the machine for the neces-
sary data.
• Data which CS Remote Care handles can be divided into the following groups.
a. Data which show the status of use of the machine such as total count, PM count.
b. Data which show the abnormal situation on the machine such as where and how
often errors occur.
c. Data on adjustment
d. Data on setting
13.15.2
SETTING UP THE CS REMOTE CARE
NOTE
• The following describes how to set up the CS Remote Care from the Service Mode
on the control panel.
In addition to the set-up from the control panel, the CS Remote Care can be set
from the PageScope Web Connection.
• For resetting up the machine which CS Remote Care has already been set up,
clear the RAM for CS Remote Care before resetting.
See P.184
Two-way communication
One-way communication
Step
Procedure
0
Register the device ID to the application at CS Remote Care center.
The initial connection is not available unless the device ID is registered.
1
Clearing the RAM for CS Remote Care
1.
Select [SERVICE MODE]
o
[PS / PCL]
o
[CS REMOTE CARE]
o
[RAM CLEAR].
2.
Select [Yes], and press the Select key.
See P.184
2
Setting the date and time for CS Remote Care
1.
Select [SERVICE MODE]
o
[PS / PCL]
o
[CS REMOTE CARE]
o
[CSRC CLOCK].
2.
Select [DATE], [TIME] or [TIME ZONE], and press the Select key.
3.
Input the date, time or time zone, and press the Select key.
See P.181
3
Setting the communication method
Select [SERVICE MODE]
o
[PS / PCL]
o
[CS
REMOTE CARE]
o
[BASIC SET-
TING]
o
[COMM. METHOD].
2.
Select [DUPLEX], and press the Select key.
Setting the communication method
1.
Select [SERVICE MODE]]
o
[PS / PCL]
o
[CS
REMOTE CARE]
o
[BASIC SET-
TING]
o
[COMM. METHOD].
2.
Select [SIMPLEX], and press the Select key.
4
Inputting the ID code
1.
Select [SERVICE MODE]
o
[PS / PCL]
o
[CS REMOTE CARE]
o
[SERVICE ENGR ID].
2.
Input the seven digits ID of the service engineer, and press the Select key.
See P.178
5
Setting the Center ID
1.
Select [SERVICE MODE]
o
[PS / PCL]
o
[CS REMOTE CARE]
o
[BASIC SET-
TING]
o
[CENTER ID].
2.
Input the five digits ID of the CS Remote Care center, and press the Select key.
See P.179
d-Color MF2400
Содержание PF-P09
Страница 1: ...SERVICE MANUAL Color Printer d Color MF2400 PF P09 Code Y113750 1...
Страница 4: ...ii Blank Page...
Страница 27: ...SERVICE MANUAL Color Printer d Color MF2400 Code Y113750 1...
Страница 151: ...7 OTHER MAINTENANCE ITEM Field Service Ver 1 1 May 2011 108 MAINTENANCE Blank Page d Color MF2400...
Страница 436: ...SERVICE MANUAL Color Printer Code Y113750 1 SERVICE MANUAL PF P09...
Страница 440: ...Lower Feeder Unit PF P09 OUTLINE MAINTENANCE Field Service Ver 1 1 May 2011 ii ADJUSTMENT SETTING Blank Page...
Страница 442: ...1 PRODUCT SPECIFICATIONS Field Service Ver 1 1 May 2011 2 Lower Feeder Unit PF P09 OUTLINE Blank Page...
Страница 454: ...3 OTHER MAINTENANCE ITEM Field Service Ver 1 1 May 2011 14 Lower Feeder Unit PF P09 MAINTENANCE Blank Page...
Страница 457: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 12 2011 1ST EDITION 457 Y113750 1...