![Olivetti FL X1 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/olivetti/fl-x1/fl-x1_user-manual_3807012024.webp)
FL X1 User Manual
24
3
TECHNICAL FEATURES
Temperature Detection
Accuracy (closeness of the measurements to a specific value)
0.1
℃
Discrepancy (closeness of the measurements to each other)
±0.3
℃
Alert default setting
Temperature > 37.3
℃
Detection distance (horizontal)
35~50cm
Temp Detect Range
30
℃
~
45
℃
Operating Temp.
15
℃
~35
℃
(indoor)
Mask detection
Response Time
< 0,5 sec
Precision
> 99%
Storage capacity
50.000 Capture Records
Detecting Range (vertical)
0.8~2.2m, adjustable angle
Face angle
Horizontal: 30° Vertical: 30°
Camera Specifications
Camera
Binocular camera, Visible and near infrared, Support live body
detection
MegaPixels
2.1 Mega Pixels (1920*1080)
Minimum Illumination
multicolor 0.01Lux @F1.2(ICR); Black and white 0.001Lux @F1.2 (ICR)
Signal to Noise Ratio
≥50db(AGC OFF)
Wide Dynamic
120db
,
ISP algorithm face partial exposure
Image sensor
1/2.8" Progressive Scan CMOS
Interfaces
Digital Output
1 KZ_Out
Interfacce di rete
1 RJ45 10M / 100M adaptive Ethernet port
USB
1
Wiegand
1 WG in, 1 WG out
RS485
RS485+ / RS485