7. Soft Switch
Field Service Ver. 2.0 Dec. 2008
66
FK-507
Adjustment / Setting
MODE
Factory setting bit
056
Bit:
7
6
5
4
3
2
1
0
0
0
0
0
1
1
0
0
HEX: 0C
Bit
Feature
Logic
Description
0
1
2
Select sending time of
ANSam.
Bit 2-0:
000
2.0 sec
1
001
2.5 sec
0
010
3.0 sec
011
3.5 sec
100
4.0 sec
101
5.0 sec
110
6.0 sec
111
Not available
MODE
Factory setting bit
057
Bit:
7
6
5
4
3
2
1
0
0
0
0
1
1
0
0
1
HEX: 19
Bit
Feature
Logic
Description
0
1
7
Select the time from when
line is blocked to when
ANSam (modified answer
tone) TX starts.
Bit 7-0:
00000000 Not available
Specify the time from
when line is blocked to
when ANSam TX starts.
6
00000001 100 msec
5
|
4
00011001 2500 msec
3
|
2
11111111 25500 msec
1
0
Service Manual Y109
97
1-7
Содержание FK-507
Страница 1: ...FK 507 Option Printer SERVICE MANUAL Code Y109971 7 ...
Страница 117: ...8 Troubleshooting Field Service Ver 2 0 Dec 2008 110 FK 507 Troubleshooting Blank Page Service Manual Y109971 7 ...