Field Service Ver. 2.0 Dec. 2008
7. Soft Switch
65
FK-507
Adjustment / Setting
MODE
Factory setting bit
054
Bit:
7
6
5
4
3
2
1
0
0
1
1
1
1
0
1
0
HEX: 7A
Bit
Feature
Logic
Description
0
1
7
Time to be detected as no
sound.
Bit 7-4:
0000
Not available
6
0001
1 sec
5
|
4
0111
7 sec
|
1010
10 sec
Others
Not available
3
Control history of V.34
auto dialing.
No
Yes
Valid only when a receiver system has
V.34 modulation.
2
Modulation method for
V.34 manual, quick scan
TX.
V.17
V.34
1
Modulation method for
V.34 polling TX document.
V.17
V.34
0
Modulation method for
V.34 manual RX.
V.17
V.34
MODE
Factory setting bit
055
Bit:
7
6
5
4
3
2
1
0
0
0
0
0
0
0
1
0
HEX: 02
Bit
Feature
Logic
Description
0
1
6
Silence detection
Do not
detect
Detect
5
Silence detection level
(cut-off frequency)
Bit 5-0:
000000
950 Hz
4
000001
1000 Hz
3
000010
1050 Hz
2
000011
1100 Hz
1
000100
1150 Hz
0
000101
1200 Hz
Others
Not available
Y109971-7 Sevice Manual
Содержание FK-507
Страница 1: ...FK 507 Option Printer SERVICE MANUAL Code Y109971 7 ...
Страница 117: ...8 Troubleshooting Field Service Ver 2 0 Dec 2008 110 FK 507 Troubleshooting Blank Page Service Manual Y109971 7 ...
Страница 118: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 02 2009 1ST EDITION 118 Y109971 7 ...