Field Service Ver. 2.0 Dec. 2008
7. Soft Switch
61
FK-507
Adjustment / Setting
MODE
Factory setting bit
046
Bit:
7
6
5
4
3
2
1
0
0
0
1
0
1
0
0
0
HEX: 28
Bit
Feature
Logic
Description
0
1
4
Call hold guard timer.
Bit 4-3:
00
1 hr
3
01
10 hr
10
24 hr
11
72 hr
2
Display symbol rate.
No
Yes
Symbol rates are 2400/2743/2800/3000/
3200/3429.
Rate of 2743 is not actually used.
1
Observe EQM:
Check modem & line sta-
tuses
No
Yes
Do not change the set value.
0
Observe probing informa-
tion.
Check modem & line sta-
tuses.
No
Yes
Do not change the set value.
MODE
Factory setting bit
047
Bit:
7
6
5
4
3
2
1
0
1
0
0
0
1
0
0
0
HEX: 88
Bit
Feature
Logic
Description
0
1
7
Select V. 34 fall back toler-
ance. (TX)
Bit 7-5:
000
0
6
001
1
5
010
2
011
3
100
4
Others
Not available
4
Select V. 34 fall back toler-
ance. (RX)
Bit 4-2:
000
0
3
001
1
2
010
2
011
3
100
4
Others
Not available
Y109971-7 Sevice Manual