Field Service Ver. 2.0 Dec. 2008
7. Soft Switch
59
FK-507
Adjustment / Setting
MODE
Factory setting bit
044
Bit:
7
6
5
4
3
2
1
0
1
0
0
0
0
0
1
0
HEX: 82
Bit
Feature
Logic
Description
0
1
7
Select threshold value for
RTN sending error trace.
32 lines
or more
64 lines
or more
Specifies # of error lines as reference of
sending RTN:
• “32 lines or more”:
MCF if error lines are 0 to 31 RTN if
error lines are 32 or more
• “64 lines or more”:
MCF if error lines are 0 to 31 RTP if
error lines are 32 to 63 RTN if error
lines are 64 or more
6
Process TCF sending
specially.
No
Yes
4
Select T4 timer.
(Action against line delay)
3 sec
4.5 sec
3
Take an action against
communication error from
overseas. (Action against
LMCD-OFF)
No
Yes
Select “No” unless bad line is experi-
enced.
2
Take an action against
communication error from
overseas.
(Action for fall back)
No
Yes
Select “No” unless bad line is experi-
enced.
1
Process RTN RX failure.
No
(discard
as error)
Yes
(not as
error)
Changes high-speed signal sending tim-
ing:
0: DCF/TCF 80 ms, CFR/PIX 450 ms
1: DCF/TCF 250 ms, CFR/PIX 600 ms
0
Retrain V. 34 control
channel.
No
(discard
as error)
Yes
(answer)