7. Soft Switch
Field Service Ver. 2.0 Dec. 2008
42
FK-507
Adjustment / Setting
7.3
List of Soft Switches
NOTE
• If no bit settings are given in the soft switch list that follows, the factory settings
for those particular bits are fixed and should never be changed.
NOTE
• The features with (*) are settable by users. *: Screen setting <*>: Soft switch set-
ting
: Default settings of U.S.
: Default settings of Europe
: Default settings are common
MODE
Factory setting bit
000
Bit:
7
6
5
4
3
2
1
0
0
0
1
1
0
0
0
0
HEX: 30 (For U.S.)
HEX: 20 (For Europe)
Bit
Feature
Logic
Description
0
1
5
Specifies whether print-
ing TSI on transmitted
document is returned to
ON or OFF after complet-
ing operations. <*>
OFF
ON
4
Select position of TSI. <*>
Out of
Doc.
On the
Doc.
3
Specifies whether con-
firming communication
password at TX is
returned to ON or OFF
after completing opera-
tions. <*>
OFF
ON
2
Confirm communication
password at RX. <*>
No
Yes
1
Specifies which TX
method is returned to ON,
memory-stored TX or
quick scan TX, after com-
pleting operations. *
Memory-
stored
Quick
scan
Memory-stored TX includes quick mem-
ory TX.
MODE
Factory setting bit
001
Bit:
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
HEX: 00
Bit
Feature
Logic
Description
0
1
0
Specify whether to insert
a destination name on
document to send.
No
Yes
Service Manual Y109
97
1-7