3K5
1-3-4
U068
Adjusting the scanning position for originals from the DP
Description
Adjusts the position for scanning originals from the DP. Performs the test copy at the four scanning positions
after adjusting.
Purpose
Used when the image fogging occurs because the scanning position is not proper when the DP is used. Run
U071 to adjust the timing of DP leading edge when the scanning position is changed.
Setting
1. Press the start key.
2. Select [ADJUST DATA] of the screen for selecting an item.
3. Change the setting using the +/- or numeric keys.
When the setting value is increased, the scanning position moves to the right and it moves to the left
when the setting value is decreased.
4. Press the start key. The value is set.
5. Select [TEST POSITION] of the screen for selecting an item.
6. Select the scanning position using the +/- or numeric keys.
7. Press the start key. The value is set.
8. Set the original (the one which density is known) in the DP and press the system menu key. The screen
for the test copy mode is displayed.
9. Press the start key. Test copy is executed.
10. Perform the test copy at each scanning position with the setting value from 0 to 3 and check that no
black line appears and the image is normally scanned.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
Setting
range
Initial
setting
Change in
value per step
ADJUST DATA
Starting position adjustment for
scanning originals
-33 to 33
0
0.086 mm
TEST POSITION
Scanning position for the test copy
originals
0 to 3
0
0.22 mm
Service Manual Y108671-9
Содержание DP-670
Страница 1: ...DP 670 DP 670 B Option Copier SERVICE MANUAL Code Y108671 9 ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 16: ...3K5 1 1 4 This page is intentionally left blank Service Manual Y108671 9 ...
Страница 20: ...3K5 1 2 4 This page is intentionally left blank Service Manual Y108671 9 ...
Страница 68: ...3K5 1 3 48 This page is intentionally left blank Service Manual Y108671 9 ...
Страница 86: ...3K5 1 6 4 This page is intentionally left blank Service Manual Y108671 9 ...
Страница 90: ...3K5 2 1 4 This page is intentionally left blank Service Manual Y108671 9 ...
Страница 103: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 06 2010 1ST EDITION 103 Y108671 9 ...