(3) Detaching and refitting the press roller
Follow the procedure below to replace the press roller.
Procedure
1. Remove the fuser unit (see page 1-5-40).
2. Remove four claws and remove the fuser
unit cover.
3. Remove two connectors.
Figure 1-5-79
4. Remove four screws.
5. Separate the right fuser frame and left fuser
frame.
Figure 1-5-80
Fuser unit cover
Claw
Connector
Connector
Claw
Claw
Claw
Screw
Screw
Right fuser frame
Left fuser frame
Screw
Screw