2H0/2HZ
1-4-18
1-4-2 Self-diagnosis
(1) Self-diagnostic function
This unit is equipped with a self-diagnostic function. When a problem is detected, copying is disabled and the problem dis-
played as a code consisting of C followed by a number, indicating the nature of the problem.
A message is also displayed requesting the user to call for service.
After removing the problem, the self-diagnostic function can be reset by turning the main power switch off and back on.
List of system errors
When an unexpected error is detected for some reason, a system error will be indicated. After a system error is indicated,
the error can be cleared by turning the main power switch off and then on. If the error is detected continuously, however,
perform the operation shown in Table 1-4-1. If a system error occurs frequently, a fault may have occurred. Check the
details of the C call to take proper measures.
Table 1-4-1
In addition, it is a system error if the following error code is displayed. When an error has occurred, clear the error by
turning the main power switch off then on.
CF1XX, CF2XX, CF3XX, CF4XX, CF5XX, CF6XX, CF7XX, CFAXX, CFBXX, 0xFBXX
Partial operation control
If any of the following calls for service is detected, partial operation control will be activated. After taking measures against
the cause of trouble, run maintenance item U906 to reset partial operation control.
Measures against the service codes detecting fuser problems
If one of the following service codes is detected, take actions to clear the cause of the trouble and perform maintenance
item U163 to reset the service code.
System error
Contents
Operation
0420
Optional paper feeder communication problem System error
→
service call
→
partial operation
0440
Optional document finisher/built-in finisher
communication problem
System error
→
service call
→
partial operation
4200
BD steady-state problem
System error
→
Normal service call processing
9000
Optional DP communication problem
System error
→
service call
→
partial operation
Code
Contents
C0180
Machine number mismatch error
Code
Contents
C6000
Fuser heater break
C6020
Abnormally high fuser thermistor temperature
C6050
Abnormally low fuser thermistor temperature
C6120
Abnormally high fuser thermistor temperature
C6150
Abnormally low fuser thermistor temperature
C6400
Zero-cross signal error
C6420
Fuser unit fuse cut problem
Service Manual
Y108620-5
Содержание d-Copia 2500MF
Страница 1: ...d Copia 2500MF d Copia 3000MF Digital Copier SERVICE MANUAL Code Y108620 5...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 14: ...2H0 2HZ This page is intentionally left blank...
Страница 20: ...2H0 2HZ 1 1 6 This page is intentionally left blank Service Manual Y108620 5...
Страница 258: ...2H0 2HZ 2 1 20 This page is intentionally left blank Service Manual Y108620 5...
Страница 296: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 296 Y108620 5...