Check procedures/
corrective measures
If the I/F connector pins of the fuser unit and
the main unit are deformed owing to foreign
matters, such as paper dusts, replace the
connectors or the units including the con-
nectors.
Remove the power cord and check that the
resistance between terminals T1 and T2 of
the triac TRA51 is of several Mega-Ohms
and not shorted (see figure 1-4-4). If failed,
replace the power source PWB (see page 1-
5-28).
Code
6000/
6020/
6030
Com-
bined
Contents
Broken fuser heater wire
Abnormally high fuser
thermistor temperature
Broken fuser thermistor
wire
Causes
Deformed connec-
tor pin.
Defective triac.
T1
T2
TRA51
Power source PWB
Figure 1-4-4
6400
Zero-cross signal error
The zero-cross signal does
not reach the engine PWB for
more than 1 s.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Power source PWB (YC103) and relay PWB
(YC1)
Relay PWB (YC4) and engine PWB (YC9)
Replace the power source PWB or the
engine PWB and check for correct operation
(see page 1-5-28, 1-5-26).
Defective power
source PWB or
engine PWB.
1-4-23
Содержание d-COLOR P2026
Страница 1: ...d Color P2021 d Color P2026 SERVICE MANUAL...
Страница 3: ...This page is intentionally left blank...
Страница 9: ...This page is intentionally left blank...
Страница 13: ...This page is intentionally left blank...
Страница 33: ...This page is intentionally left blank 1 2 14...
Страница 54: ...This page is intentionally left blank 1 3 21...
Страница 95: ...This page is intentionally left blank 1 4 41...
Страница 141: ...4 Remove the paper conveying unit 1 Paper conveying unit 2 2 Figure 1 5 71 1 5 47...
Страница 177: ...This page is intentionally left blank 2 2 8...