Check procedures/
corrective measures
Check to see if the bottom plate can move
smoothly and repair it if any problem is
found.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
PF lift motor and PF main PWB (YC7)
Check if the gears rotate smoothly. If not,
grease the bushes and gears. Check for
broken gears and replace if any.
Replace the PF lift motor
Replace the PF main PWB (Refer to the ser-
vice manual for the paper feeder).
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
PF fan motor 1 and PF main PWB (YC111)
Replace the top heater unit (Refer to the
service manual for the paper feeder).
Replace the top heater unit (Refer to the
service manual for the paper feeder).
Replace the PF main PWB (Refer to the ser-
vice manual for the paper feeder).
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
PF fan motor 2 and PF main PWB (YC111)
Replace the side heater unit (Refer to the
service manual for the paper feeder).
Replace the side heater unit (Refer to the
service manual for the paper feeder).
Replace the PF main PWB (Refer to the ser-
vice manual for the paper feeder).
Code
1040
Contents
PF lift motor error
(paper feeder 3)
When the lift motor is driven,
the motor over-current detec-
tion signal is detected continu-
ously for 50 times (5 s) at 100
ms intervals.
After the lift motor is driven,
the ON status of lift sensor
cannot be detected for 8 s.
The cassette installed confir-
mation message is displayed
on the operation panel, and
even if the cassette is opened
and closed, the cassette
installed confirmation mes-
sage is displayed 5 times suc-
cessively.
PF heater 1 high tempera-
ture error
(paper feeder 1)
A temperature higher than
75 C/167 F is detected.
Causes
Defective bottom
plate elevation
mechanism in the
cassette.
Defective connec-
tor cable or poor
contact in the con-
nector.
Defective drive
transmission sys-
tem of the PF lift
motor.
Defective PF lift
motor.
Defective PF main
PWB.
Defective connec-
tor cable or poor
contact in the con-
nector.
Shorted PF therm-
istor 1.
Defective PF fan
motor 1.
Defective PF main
PWB.
1500
1510
PF heater 2 high tempera-
ture error
(paper feeder 1)
A temperature higher than
75 C/167 F is detected.
Defective connec-
tor cable or poor
contact in the con-
nector.
Shorted PF therm-
istor 2.
Defective PF fan
motor 2.
Defective PF main
PWB.
1-4-10
Содержание d-COLOR P2026
Страница 1: ...d Color P2021 d Color P2026 SERVICE MANUAL...
Страница 3: ...This page is intentionally left blank...
Страница 9: ...This page is intentionally left blank...
Страница 13: ...This page is intentionally left blank...
Страница 33: ...This page is intentionally left blank 1 2 14...
Страница 54: ...This page is intentionally left blank 1 3 21...
Страница 95: ...This page is intentionally left blank 1 4 41...
Страница 141: ...4 Remove the paper conveying unit 1 Paper conveying unit 2 2 Figure 1 5 71 1 5 47...
Страница 177: ...This page is intentionally left blank 2 2 8...