(2) Detaching and refitting the power source PWB
Procedure
1. Remove the top cover (see page 1-5-3).
2. Remove the right rear cover, right cover
and right lower cover (see page 1-5-5).
3. Remove three screws and then remove
the power source shield.
Screws A and B are unidentical, there-
fore, do not mix up.
Screw A
Screw B
Power source shield
Screw A
Figure 1-5-39
4. Remove all connectors from power
source PWB.
5. Remove two screws.
6. Release three hooks and then remove
the power source PWB.
7. Check or replace the power source
PWB and refit all the removed parts.
Hook
Hook
Hook
YC104 YC103 YC105
YC101
YC102
Screw
Power source PWB
Screw
Figure 1-5-40