Paper feed motor cable, ID
motor cable, belt motor cable,
ID up motor cable, fuser motor
cable
Paper feed motor cable, belt
motor cable, ID up motor
cable
Paper feed motor, belt motor,
ID up motor
Confirmation Tasks
Check the cable connection.
By visual inspection, check whether incompletely connection
and oblique insertion of HOP connector, CID connector, BELT
connector, IDUP connector and HEAT connector or defective
cable assembly exists.
Check whether wire gnawing occurred during assembly of
equipment.
Pull the HOP connector of main board (TB3 PCB) out, check
the followings on the cable side.
SEVERAL M‰ Between 1pin-FG
SEVERAL M‰ Between 2pin-FG
SEVERAL M‰ Between 3pin-FG
SEVERAL M‰ Between 4pin-FG
Pull the BELT connector of main board (TB3 PCB) out, check
the followings on the cable side.
SEVERAL M‰ Between 1pin-FG
SEVERAL M‰ Between 2pin-FG
SEVERAL M‰ Between 3pin-FG
SEVERAL M‰ Between 4pin-FG
Pull the IDUP connector of main board (TB3 PCB) out, check
the followings on the cable side.
SEVERAL M‰ Between 1pin-FG
SEVERAL M‰ Between 2pin-FG
SEVERAL M‰ Between 3pin-FG
SEVERAL M‰ Between 4pin-FG
Pull each connector out of the board, and check the following
resistance value between terminals on the cable side.
HOP connector of main board (TB3 PCB)
Between 1pin-2pin: about 3.5‰ or 4.4‰
Between 3pin-4pin: about 3.5‰ or 4.4‰
BELT connector of main board (TB3 PCB)
Between 1pin-2pin: about 3.5‰ or 4.4‰
Between 3pin-4pin: about 3.5‰ or 4.4‰
IDUP connector of main board (TB3 PCB)
Between 1pin-2pin: about 7‰ or 6.7‰
Between 3pin-4pin: about 7‰ or 6.7‰
Action at NG
Assemble normally.
Replace the cable with
a new one.
Replace the cable with
a new one, and
reassemble correctly.
Replace the paper
feed motor, belt motor,
ID up motor with a new
one.
(5-2-4) Check the connection
Confirmation Items
168
d-Color P116 Service Manual
Y110260-4