Display
Cause
Details of error
Method
Table 7-1-2 service call error list (6/6)
Service call
231: Error
Service call
240: Error
Power off/on
901:Error
902:Error
Power off/on
903:Error
904:Error
Power off/on
923: Error
Power off/on
928:Error
Service call
980: Error
Service call
983: Error
Power off/on
F0C: Error
F0D:Error
Power off/on
FFF: Error
RFID Reader I/F
Error
Engine Program
Memory Error
Short or open in
belt thermistor
detected.
Abnormal
temperature
detected by belt
thermistor (high-
temp or low
temp.)
Image Drum
Lock Error
Fuser MotorLock
Error
Media coiling
error to the fuser
Error due to
detection of the
toner cartridges
of the same color
System Call
Exception
Bus controller
ROM Write
protection
An interface error was detected with
the RFID reader device.
01: communication error between
the RFID reader and the engine PCB.
02: the transceiver circuit error of the
RFID reader.
03: communication error between the
RFID reader and the Tag chip.
04: the RFID Tag detection error
(more than 4chips).
240: Flash Memory
Hardware Error
Is belt thermistor cable setting
proper?
Does error reoccur?
Is belt thermistor cable setting
proper?
Does error reoccur?
The ID motor does not rotate
correctly.
Is the error message displayed when
the power is turned on again?
The fuser unit does not rotate
properly.
Does the error reoccur after power
cycling?
Media is coiled to the fuser
Two or more toner cartridges of the
same color are detected
Yes
Yes
No
Yes
Yes
No
Yes
Yes
Yes
Yes
01: Same as Error 230.
02: Replace the LUM board
(RFID reader/writer board).
03: Check the connection of the
antenna cable.
04: Check if the number of RFID
Tags is correct.
If the error occurs again after re-
turning on the power supply, replace
the board of the unit.
Connect cable set properly again.
Turn power ON again.
Replace belt thermistor.
Connect cable set properly again.
Turn power ON again.
Replace belt thermistor and leave
aside for 30 min. Then turn power
ON again.
Check if the ID unit is set correctly.
Replace the ID unit.
Replace the ID motor.
Check to see if the fuser unit is
properly installed.
Replace the fuser unit.
Replace the fuser motor.
Turn off the power supply
Replace the fuser
Install the cartridge of the specified
in the specified position
Turn on the power supply again.
Turn on the power supply again.
Note!
Because service call 168 error ,171 error and 175 error may occur when the temperature of
printer is below zero, please restart the printer after making it warm when the temperature
of printer is low.
Y110260-4
d-Color P116 Service Manual
149