Description
Level
Ready
LED
Attention
LED
LCD (English)
(
■
■
means no display in upper line)
■
■
DENSITY BLACK CALIBRATION
ERROR
■
■
DENSITY BLACK SENSOR ERROR
SENSOR CALIBRATION ERROR
■
■
%COLOR% IMAGE DRUM SMEAR
ERROR
■
■
%COLOR% LOW DENSITY ERROR
■
■
SENSOR CALIBRATION ERROR
Varies
Varies
Varies
Varies
Varies
Varies
Varies
Varies
On
Varies
Varies
On
Density Adjustment Black Calibration Error.Error that
does not occur at user level.Displayed only in
FactoryMode.
PU firmware does not notify this warning to CU firmware
at the time of Shipping Mode. Therefore, this status does
not occur in a user environment.
Density Adjustment Black Sensor Error.Error that does
not occur at user level.Displayed only in FactoryMode.
PU firmware does not notify this warning to CU firmware
at the time of Shipping Mode. Therefore, this status does
not occur in a user environment.
Sensor calibration error
This error does not occur in the user’s environment
because the PU firmware does not notify the CU
firmware of this status detected in Shipping Mode.
Density Adjustment ID ERROR 2; smear due to ID
failure.
PU firmware does not notify this warning to CU firmware
at the time of Shipping Mode. Therefore, this status does
not occur in a user environment.
Y
M
C
K
Density Adjustment ID ERROR; LED out of focus is
assumed.
PU firmware does not notify this warning to CU firmware
at the time of Shipping Mode. Therefore, this status does
not occur in a user environment.
Y
M
C
K
When output of color registration sensor is below
reference value.
PU firmware does not notify this warning to CU firmware
at the time of Shipping Mode. Therefore, this status does
not occur in a user environment.
Warning
Warning
Warning
Warning
Warning
Warning
Y110260-4
d-Color P116 Service Manual
123