• When print is executed, the following message is displayed:
P=***
W=***
T=*** U=***[###]
H=*** %L=***[###]
KR=*.** YR=*.**
MR=*.** CR=*.**
KTR=*.** YTR=*.**
MTR=*.** CTR=*.**
ETMP=*** UTMP=***
REG=**** EXT=***
P: Number of test-print pages (Unit: sheets)
W: Print wait time (Unit: seconds)
• Pressing the MENU+ key switches over the indication.
U: *** = Measured value of upper heater temperature [Unit: ˚C]
[###] = Target temperature for print execution [Unit: ˚C]
L : *** = Measured value of lower thermistor [Unit: ˚C]
[###] = AD value of lower thermistor reading [Unit: HEX]
T: Measured value of environmental temperature [Unit: ˚C]
H: Measured value of environmental humidity [Unit: %]
• Pressing the MENU+ key switches over the indication.
YTR, MTR, CTR and KTR denote the transfer voltage set values of the respective colors (Unit: KV).
• Pressing the MENU+ key switches over the indication.
KR: BLACK transfer roller resistance value [Unit: uA]
YR: YELLOW transfer roller resistance value [Unit: uA]
MR: MAGENTA transfer roller resistance value [Unit: uA]
CR: CYAN transfer roller resistance value [Unit: uA]
• Pressing the MENU+ key switches over the indication.
ETMP: Hopping motor constant-speed correction parameter (Environmental temperature)[Unit: DEC]
UTMP: Fuser motor constant-speed correction parameter (Target fuser temperature)[Unit: DEC]
REG: Hopping motor constant-speed timer value (I/O set value)[Unit: HEX]
EXT: Fuser motor constant-speed timer value (I/O set value)[Unit: HEX]
Y110260-4
d-Color P116 Service Manual
107