12. SERVICE MODE
Field Service Ver. 2.0 Jul. 2009
464
ADJUSTMENT
/ SETTING
12.4.4
Org. Size Detecting Sensor Adj.
A. Use
• To automatically adjust the original detection distance for the original size detection sen-
sor/1.
• To display if the original size detection sensor/2 is mounted.
• When the sensor is replaced with a new one.
• When an optional sensor has been added.
• When an erroneous original size detection is made.
• When the marketing area setting is changed.
B. Procedure
1.
Place a blank sheet of A3 or 11 x 17 paper on the original glass and lower the original
cover.
2.
Call the Service Mode to the screen.
3.
Touch these keys in this order: [Machine]
o
[Org. Size Detecting Sensor Adj.].
4.
Press the Start key.
If the adjustment has been successfully made, it completes the adjustment procedure.
If the adjustment has turned out to be unsuccessful, check the optional original size sen-
sors for correct installation and change the defective sensor or harness.
Service Manual Y110571-1
Содержание d-color MF651
Страница 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Страница 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 511: ...Field Service Ver 2 0 Jul 2009 10 UTILITY 451 ADJUSTMENT SETTING Blank Page Y110571 1 Service Manual...
Страница 716: ...16 MECHANICAL ADJUSTMENT Field Service Ver 2 0 Jul 2009 656 ADJUSTMENT SETTING Blank Page Service Manual Y110571 1...
Страница 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...