Field Service Ver. 2.0 Jul. 2009
22. IMAGE QUALITY PROBLEM
857
TROUBLESHOOTING
22.1.2
Level history 1
TCR-C
TCR-M
TCR-Y
TCR-K
• Shows the T/C ratio (in 0.01 % increments).
• Standard value: 6 to 8 %
• Relevant components: TCR sensor
IDC1
IDC2
• Shows the IDC bare surface output value (in 0.01 V increments).
• It should normally be around 4.3 V.
• The output range is 0 V to 5 V.
• Relevant components: IDC sensor, transfer belt unit
Middle heat temperature
Heat. Protect Tempera-
ture
Heat edge temperature
Soaking side temperature
NC sensor temperature
• Shows the temperature of the each part of the fusing unit
(in 1
q
C increments).
• Relevant components: Fusing unit