Field Service Ver. 2.0 Jul. 2009
19. TROUBLE CODE
731
TROUBLESHOOTING
C3B05 IH temperature sensor
defect
• While the IH heater was on, IH temperature
sensor was disconnected for more than the
predetermined period of time.
• While the IH heater was on, short circuit on
IH temperature sensor continued for more
than the predetermined period of time.
• While the IH heater was on, temperature
change occurred within the predetermined
period of time with over the predetermined
range, and they continued for more than the
predetermined period of time.
• While the IH heater was on, temperature
around the heat radiator stayed high for over
the predetermined period of time.
A
C3B06 IH surge error
• While the IH heater was on, IH stopped due
to input voltage which exceeded that of
surge detection voltage, and the surge
detection voltage continued for more than
the predetermined period of time.
A
C3B07 IH input power error
• While the IH heater was on, input power
stayed at the high voltage power detection
value or over for more than the predeter-
mined period of time.
• While the IH heater was on, input power
was at the low power detection value or
under for more than the predetermined
period of time.
• While the IH heater was on, input power
was at the high voltage detection value or
over for more than the predetermined period
of time.
• While the IH heater was on, input power
was below the low voltage detection value or
under for more than the predetermined
period of time.
• While the IH heater was on, inverter power
stayed at the upper limit value or over for
more than the predetermined period of time.
• While the IH heater was on, output voltage
halt was detected.
A
C3B08 IH input voltage error
• While the IH heater was on, input power
was at the high voltage detection value or
over for more than the predetermined period
of time.
• While the IH heater was on, input voltage
was at the low power detection value or
under for more than the predetermined
period of time.
B
C4101 Polygon motor rotation
trouble
• The polygon motor fails to turn stably even
after the lapse of a given period of time after
activating the polygon motor.
• Motor lock signal detects HIGH for a given
period time consecutively during the poly-
gon motor is rotating.
B
Code
Item
Detection timing
Trouble iso-
lation
Rank
Y110571-1 Service Manual
Содержание d-color MF651
Страница 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Страница 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 511: ...Field Service Ver 2 0 Jul 2009 10 UTILITY 451 ADJUSTMENT SETTING Blank Page Y110571 1 Service Manual...
Страница 716: ...16 MECHANICAL ADJUSTMENT Field Service Ver 2 0 Jul 2009 656 ADJUSTMENT SETTING Blank Page Service Manual Y110571 1...
Страница 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...