12. SERVICE MODE
Field Service Ver. 2.0 Jul. 2009
546
ADJUSTMENT
/ SETTING
(2) New Release
• After replacing a fusing unit or transfer belt unit, perform New Release to clear its life
counter.
1.
Select the key as follows.
[Counter]
o
[Life]
o
[New Release].
2.
Open the lower front door.
3.
Select a unit where New Release is made.
4.
Press the Start key and perform New Release.
(3) New Release Disable mode
• To enable a unit that is used temporarily for troubleshooting to be used again as a new
unit in another machine, the New Release Disable mode is provided.
• Applicable units are the following units that have the new unit detection feature
Imaging unit/Y,M,C, drum unit/K, developing unit/K
• See the following page for the method of enabling the New Release Disable mode.
See P.623
12.10.3
Service Call Counter
A. Use
• To count and display how many times trouble has been detected on a trouble type basis.
• Use this feature to check how many times trouble has occurred.
NOTE
• In the service call counter list, “Reboot” shows how many times abort code (C-
FXXX) has occurred.
12.10.4
Section Service Call
A. Use
• To count and display how many times trouble has been detected during a certain period,
i.e. an interval between service visits, on a trouble type basis.
• Use this feature to check how many times trouble has occurred in a certain period, i.e. an
interval between service visits.
• By clearing the counter at the time of visit to your customer, i.e. service visit, you can
check how many times trouble has occurred since the previous visit.
To reset the counter, use [Counter Reset].
NOTE
• In the zone service call list, “Reboot” shows how many times abort code (C-FXXX)
has occurred.
12.10.5
Warning
A. Use
• To count and display how many times warning code has been detected on a warning
code type basis.
• To check the number of warning conditions detected according to the warming type
B. Procedure
• To clear the count of a counter, select the specific part and press the Clear key.
• If a counter is cleared mistakenly, press the Interrupt key, which will undo the clearing
operation.
• When a warning condition occurs, an oil mark appears at the lower left corner of the
basic screen.
• Touching the oil mark will display the warning code screen.
Service Manual Y110571-1
Содержание d-color MF651
Страница 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Страница 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 511: ...Field Service Ver 2 0 Jul 2009 10 UTILITY 451 ADJUSTMENT SETTING Blank Page Y110571 1 Service Manual...
Страница 716: ...16 MECHANICAL ADJUSTMENT Field Service Ver 2 0 Jul 2009 656 ADJUSTMENT SETTING Blank Page Service Manual Y110571 1...
Страница 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...