Field Service Ver. 2.0 Jul. 2009
12. SERVICE MODE
477
ADJUSTMENT
/ SETTING
12.4.17
Skew adjustment-Skew adjustment
A. Use
• This function allows you to set the default position of the skew correction motor.
• Adjusts and sets a value that is used as an individual skew correction motor's reference
position for skew correction control.
• This setting is made after the PH unit is replaced.
• Use this function when the information of the motor’s position setting is lost due to the
replacement of the service EEPROM board or other reasons.
B. Procedure
1.
Call the Service Mode to the screen.
2.
Touch these keys in this order:
[Machine]
o
[Skew adjustment]
o
[Skew adjustment].
3.
Select the color to be set.
4.
Enter the skew value described on the new PH unit with the 10-key pad.
5.
Touch [OK].
6.
Proceed to [Skew adjustment reset].
12.4.18
Skew adjustment-Skew adjustment reset
A. Use
• Returns the skew correction motor to the default position and clear the backup copies of
the cumulative skew amount.
• After PH unit replacement, perform [Skew adjustment] and then execute this function.
• Use this feature when the information of the skew correction position that is backed up in
the machine is lost by replacing the service EEPROM board or other reasons.
• After addressing the alert code P-14 and completing an action to the problem, perform
this function.
• Use this function when the current skew correction motor’s position becomes unavailable
due to the skew adjustment interrupted by the door being opened or the main power
switch being turned OFF.
B. Procedure
1.
Call the Service Mode to the screen.
2.
Touch these keys in this order:
[Machine]
o
[Skew adjustment]
o
[Skew adjustment reset].
3.
Touch the start key and execute the skew adjustment reset.
NOTE
• After replacing the PH unit or service EEPROM board, set the initial position of the
skew correction as follows: [Machine]
o
[Skew adjustment]
o
[Skew adjustment].
After completing [Skew adjustment], perform [Skew adjustment reset].
• After the skew adjustment reset is complete, be sure to perform [Init Image
Stabilization].
Y110571-1 Service Manual
Содержание d-color MF651
Страница 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Страница 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 511: ...Field Service Ver 2 0 Jul 2009 10 UTILITY 451 ADJUSTMENT SETTING Blank Page Y110571 1 Service Manual...
Страница 716: ...16 MECHANICAL ADJUSTMENT Field Service Ver 2 0 Jul 2009 656 ADJUSTMENT SETTING Blank Page Service Manual Y110571 1...
Страница 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...