12. SERVICE MODE
Field Service Ver. 2.0 Jul. 2009
472
ADJUSTMENT
/ SETTING
12.4.12
Scan Area-Image Position: Side Edge
A. Use
• To adjust part-to-part variations in accuracy of scanner parts and their mounting accu-
racy by varying the scan start position in the main scan direction.
• When the CCD unit is replaced.
• When the original glass is replaced.
• The scanner home sensor has been replaced.
B. Procedure
• A width on the color chart and one on the test print are measured and adjusted so that
the difference of B width satisfies the specifications shown below.
• An adjustment must have been completed correctly of [Centering] of [Printer Area].
Specifications
B: ± 1.0 mm
1.
Call the Service Mode to the screen.
2.
Touch these keys in this order: [Machine]
o
[Scan Area]
o
[Image Position: Side
Edge].
3.
Position the color chart correctly so that the original reference point is aligned with the
scale.
4.
Press the Start key to make a copy.
5.
Check point B on the image of the test print.
6.
If the test print falls outside the specified range, change the setting using the [+] / [-]
key.
If the test print is less than the specified length, increase the setting value.
If the test print exceeds the specified length, decrease the setting value.
7.
Press the Start key to make a test print.
8.
Check point B of the image on the test print to see if the specifications are met.
9.
Make adjustments until the specifications are met.
A0P0F3C508DA
B
Service Manual Y110571-1
Содержание d-color MF651
Страница 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Страница 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 511: ...Field Service Ver 2 0 Jul 2009 10 UTILITY 451 ADJUSTMENT SETTING Blank Page Y110571 1 Service Manual...
Страница 716: ...16 MECHANICAL ADJUSTMENT Field Service Ver 2 0 Jul 2009 656 ADJUSTMENT SETTING Blank Page Service Manual Y110571 1...
Страница 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...