Field Service Ver. 2.0 Jul. 2009
10. UTILITY
369
ADJUSTMENT
/ SETTING
H. IPsec Settings
(1) Use
• To set whether to use IPsec protocol for IP network communication.
(2) Procedure
• The default setting is OFF.
ON
“OFF”
• When selecting [ON], make settings in [IKE Setting], [IPSec SA Setting], and [Peer].
I.
IPsec Settings-IKE Settings
(1) Use
• To make the settings that relate to IKE (Internet Key Exchange) protocol which is used
for IPsec communication.
• Settings can be made independently for four different sets (Group 1 to 4).
(2) Procedure
<Group>
• Among four groups (Group 1 to 4), select a group where settings are made.
<Encryption Algorithm>
• Set a encryption algorithm used for IPsec communication.
• The default setting is OFF.
DES_CBC
3DES_CBC
“OFF”
<Authentication Algorithm>
• Set an authentication algorithm used for IPsec communication.
• The default setting is OFF.
MD5
SHA-1
“OFF”
<Key Validity Period>
• Set a key validity period.
• The default setting is 28800 (sec.).
80 to 604800 (sec.)
<Diffie-Hellman Group>
• Set Diffie-Hellman group.
• The default setting is Group 2.
Y110571-1 Service Manual
Содержание d-color MF651
Страница 1: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 24: ...MEASURES TO TAKE IN CASE OF AN ACCIDENT S 22 Blank Page...
Страница 27: ...d Color MF651 d Color MF551 d Color MF451 Color Printer SERVICE MANUAL Code Y110571 1...
Страница 511: ...Field Service Ver 2 0 Jul 2009 10 UTILITY 451 ADJUSTMENT SETTING Blank Page Y110571 1 Service Manual...
Страница 716: ...16 MECHANICAL ADJUSTMENT Field Service Ver 2 0 Jul 2009 656 ADJUSTMENT SETTING Blank Page Service Manual Y110571 1...
Страница 1053: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2009 1ST EDITION 1053053 Y110571 1...