Electricals
WARNING
All electrical work must be done by a qualified electrician and must meet the
electrical code in your area.
Minimum Circuit Size Requirement
Model
Minimum Circuit Size Required
Please ensure the electrical circuit for this machine meets the minimum circuit size requirement. The
minimum circuit size requirement applies to a dedicated circuit that provides power to one drill press. If
more machines are sharing the same circuit, consult a qualified electrician to ensure the designated circuit
is properly sized for safe operation.
If a circuit is available, but not meeting the minimum circuit size requirement listed above, a new circuit
must be installed for this machine.
Grounding
WARNING
Improper grounding can cause electric shock, fire, and equipment damage.
Proper grounding reduces the risk to the operator in the event of electrical malfunction or breakdown.
This machine must be connected to the grounding conductor when available, and all grounding
connections must meet or exceed the electrical code requirements in your area. Furthermore, all grounds
must be verified and must meet or exceed the electrical requirement of the machine. If grounding is not
available, consider the use of a GFCI protection device as an alternative, if this complies with the electric
code in your area.
Electrical Wiring
This machine is pre-wired for 115V with a cord and a NEMA 5-15 plug. Use of extension cord is not
recommended. If you need to use an extension cord to connect to a power source, select a durable cord
type with high-temperature rating (90C° or above). Use the minimum amount of extension cord as needed.
Minimum cord size (AWG) required based on amperage draw and length of the cord:
Amps
Power Cord Length
25 feet
50 feet
75 feet
100 feet
> 100 feet
< 5
16
14
14
14
NR
5 to 8
14
14
14
12
8 to 12
14
14
12
10
12 to 15
12
12
10
10
*NR: Not Recommended
WARNING
Use properly sized wires that meet or exceed the power requirement of your
machine. Using undersized wires may cause overheating and increase the risk of fire
and machine damage.
Содержание 10060
Страница 8: ...8 Page Oliver Machinery 10060 10061 Drill Press Identification...
Страница 9: ...10060 10061 Drill Press OLIVERMACHINERY NET 9 Page...
Страница 36: ...36 Page Oliver Machinery 10060 10061 Drill Press Wiring Diagram...
Страница 37: ...10060 10061 Drill Press OLIVERMACHINERY NET 37 Page Parts List...
Страница 41: ...10060 10061 Drill Press OLIVERMACHINERY NET 41 Page Maintenance Record Date Task Operator...
Страница 42: ...42 Page Oliver Machinery 10060 10061 Drill Press Notes...
Страница 45: ......