SHERPA SHW
Sanitary water heat pump
30
16
TECHNICAL CHARACTERISTICS
TECHNICAL DATA
SHW 200
SHW 300S
Power supply
V/Ph/Hz
220-240/1/50
Water tank real capacity
L
228
278
Heating capacity
W
1870* (+1200**)
Rated power input
W
503* (+1200**)
Nominal current
A
2.23* (+5.2**)
COP
W/W
3.72*
Max power input
W
765 (+1200**)
Max current
A
3.5 (+5.2**)
Max. outlet water temperature
(without using E-heater)
°C
65
Max. water temperature
°C
75**
Min. water start temperature
°C
10
Ambient working temp.
°C
-10 ~ +43
Refrigerant max. discharge pressure
bar
26
Refrigerant max. suction pressure
bar
6
Refrigerant type
R134a
Refrigerant charge
g
920
Compressor
Type
Rotary
Brand
Toshiba
Model
PJ125G1C-4DZDE
Compres
sor oil
ESTER OIL VG74, 400 mL
Fan motor
Type
Asynchronous motor
W
80
RPM
1250
Air flow without air static pressur
m3/h
450
Air flow with 60 Pa of air static pressur
m3/h
350
Duct diameter
mm
177 (Fit flexible 180 mm duct)
Max allowed pressure of tank
bar
10
Inside body material of tank
S235JR with double layer vetrification
Auxiliary electrical heater
kW
1.2
Electronic expansion valve
yes
Magnesium stick
yes
Heat pump heat exchanger material (condenser)
Aluminium alloy
Solar exchanger coil surface
m2
/
1,2
Auxiliary exchanger coil surface
m2
/
/
Solar exchanger coil flow rate***
m3/h
/
1,2
Auxiliary exchanger coil flow rate***
m3/h
/
/
Exchanger coil max. pressure
bar
/
6
Exchanger coil material
Pickled S235JR
Cold water inlet
inch
G 1”female
Hot water outlet
inch
G 1”female
Solar heat source inlet/outlet
inch
/
G 1”female
Auxiliary heat source inlet/outlet
inch
/
/
Condensed water outlet
0,3 mt.
22 mm plastic flexible pipe
Drainage
inch
To be installed externally
IP protection class
IPX1
Net Dimensions
mm
φ654x1638
φ654x1888
Packing Dimensions
mm
700x700x1760
700x700x2010
Net Weight
Kg
98.0
121.5
Weight with full water
Kg
326.0
399.5
Gross Weight
Kg
112.0
136.5
Noise level ****
dB (A)
46
NOTES:
* Capacity and power input based on the following conditions:
ambient temperature 20°C, water temperature from 15°C to 55°C (these data are obtained by internal laboratory tests based on the
uniform reintegration of the tank temperature).
**Related to the supplementary e-heater. During disinfection, the water temp could be up to 70°C by electrical heater
*** values referring to integration with boiler in accordance with DIN 4708 norms (80/60°C on primary circuit, 10/45°C on secondary circuit)