Olimpia splendid Maestro Smart Series Скачать руководство пользователя страница 12

Failing to comply with the instructions contained in this manual and using the unit with temperatures exceeding the permissible  range will 
invalidate the warranty.

 

Routine maintenance of the filters and general external cleaning can be done by the user as these operations are not difficult or

 

dangerous.

 

During the assembly and each maintenance operation, always pay attention to the warnings described in this manual and on the labels 
affixed inside the appliances, and respect anything suggested by common sense and those of the Safety Norms in  force in the place of 
installation.

 

Always wear Personal Protection Devices when servicing the unit. 

 

These units MUST NEVER be installed in rooms where flammable gas, explosive gas, or excessive humidity (laundry rooms, greenhouses, 
etc.), or in rooms where there are other units that generate excessive heat. Should components need replacing, always use 

OLIMPIA 

SPLENDID 

original spare parts. 

IMPORTANT!

 

To avoid any risk of electric shock always deenergize the unit before making electrical connections

 

or any maintenance 

procedures.

 

IMPORTANT!

 

Do not allow R-410A to escape into the atmosphere: R-410A is a fluorinated greenhouse gas, as cited in the Kyoto Protocol, with

 

a Potential Global Warming effect (GWP) = 2088.

 

1.3 

WARNING

 

The 

unit

 should be used for the exclusive purpose of producing hot or cool air for the sole purpose of obtaining a comfortable 

temperature in the room.  Improper use of the equipment, which may cause injury/damage to persons, property or animals, relieves 

OLIMPIA SPLENDID 

of any liability.

 

1.4 

LIST OF SUPPLIED COMPONENTS

 

In addition to the unit this package includes the parts listed below.  Before installing verify the parts are within easy reach. 

-  Strip of adhesive isolating tape

 

B -

  Air inlet and outlet external grids including chains and kit for installing the grids (n.2)

 

-  Internal flanges (2)

 

-  Sheet for wall pipes

 

-  Kit of screws and anchor bolts

 

-  Wall anchoring bracket

 

-  Use and maintenance manuals and warranty document

 

-  Remote control

 

I   

-  Paper template to make holes 

1.4.1 

Storage

 

Store units in an area protected from outdoor ambient conditions.  Units should be stored on pallets or beams to isolate from the ground. 

DO NOT TURN THE UNIT OVER OR DAMAGE WILL RESULT.  

1.4.2 

Receipt and unpacking

 

The products are packaged by qualified personnel using suitable packaging material. The units are shipped complete and in perfect condition 
when leaving our facility.  However, we suggest that you perform the following checks:

 

Upon receipt check if the package is damaged. If damage is found note this on the shipping documents taking photographs

 

of any

damage.

  Notify the shipper by registered mail with 3 days of receipt.

Unpack and check the contents against the packing list.

C

heck that none of the components have been damaged during transport; if damage is found notify the shipper by registered letter,

which should include photographic evidence within 3 days of receiving the unit.

Send the same information by fax to 

OLIMPIA SPLENDID

.

No claims for damage will be accepted if made more than 3 days after the delivery of the goods

.

Important note:

 

It is recommended to keep the packaging during the warranty period for any possible delivery of the product to a service center.  After the 
warranty period ends dispose of the packaging in compliance with prevailing regulations. 

1

 

10

Содержание Maestro Smart Series

Страница 1: ...INSTRUCTIONS FOR INSTALLATION USEAND MAINTENANCE Customer Service It means the world to us because customers are our world...

Страница 2: ...de Ventilation Mode Heating Mode HP model only Airflow Directional Control Checking fan speed Night Mode Cooling Night Mode Heating Setting the operating programs Setting the exact time Setting the ti...

Страница 3: ...nstalled must be sturdy and able to withstand its weight It must be possible to leave room around the unit for any maintenance operations that may be necessary Nothing can be in the way of the air tha...

Страница 4: ...ing damper or spray corrosive cleaning agents into the unit 4A to 4G Do not allow curtains or other hanging materials to block the flow of air entering or exiting the unit Do not allow airflow to dire...

Страница 5: ...5 8 9 A 6 B A 12 3...

Страница 6: ...10 A B 13 14 A 16 4...

Страница 7: ...17 18 A C B A 20 A C B D 5...

Страница 8: ...23 B 24 A B 6...

Страница 9: ...C B A E F C A D B C A B B A 7...

Страница 10: ...H D7 2 M D9 D10 T1 T3 F s T2 A E T4 N T7 T5 T6 T8 T11 T9 T10 AUTO NOTE The remote control is equipped with a sliding cover that can be positioned to permit access only to the ON OFF automatic operatin...

Страница 11: ...rly providing optimum room temperatures with minimum energy costs The manual is divided into 3 sections or chapters CHAP 1 GENERAL INFORMATION Aimed at the installer and the end user this chapter incl...

Страница 12: ...COMPONENTS In addition to the unit this package includes the parts listed below Before installing verify the parts are within easy reach A Strip of adhesive isolating tape B Air inlet and outlet exter...

Страница 13: ...es required to install the unit WARNINGS fig 4 The unit should not be placed under curtains that may block free movement of the air Do not spray water or other liquids of any kind directly on the unit...

Страница 14: ...ge of the flange as indicated in the figure Fix the two flanges using 2 pegs having a diameter of 1 4 and check that the two fixing holes are horizontal Fit the small eyelet of the spring with the lon...

Страница 15: ...which air flows upwards The same configuration may also be used to install the unit near the ceiling with the cooling function allowing an increase tothe airflow in the room Figure 21 refers to a unit...

Страница 16: ...RL OFF ON ON OFF Maximum level of condensate water OF OFF ON ON ON Invalid EEprom parameters CKS ON OFF OFF OFF Room temperature probe fault short circuit TFS1 ON ON OFF OFF Room temperature probe fau...

Страница 17: ...black active carbon filter fig 26 ref C on the filter rack fig 26 ref A and lock it to the specific tongues fig 26 ref D Fit the purifying filter green fig 26 ref B on the first pin that is on the fi...

Страница 18: ...nterface between the user and the unit It s designed to provide excellent performance when used responsibly It is sturdy but should nevertheless be handled with care For example do not leave it out in...

Страница 19: ...lable on heating pump HP models To activate heating mode press button T4 Run mode selector until the sun symbol D2 is displayed The required temperature and fan speed can be selected After a maximum o...

Страница 20: ...number 1 This allows the user to set the stop time for the 1st program Press the T7 button to increase or decrease the time you want program 1 to stop Program 1 is now set To set program 2 press the T...

Страница 21: ...al performance operational limits and physical dimensions weights consult the specifications document for this specific unit 3 FAULTS The unit does not turn on POSSIBLE CAUSES No power supply The powe...

Страница 22: ...it selection Prior to Starting the unit verify Supply Voltage to the unit _______ Install batteries in Remote Control Start Unit to verify operation and record requested values below The following val...

Страница 23: ...A completed data sheet available on www olimpiasplendidusa com must be submitted along with the warranty claim if requesting a replacement unit due to compressor failure Claims submitted with a missi...

Отзывы: