Bi2 Air
6.0 H
0 h 6.0 H
EN - 19
ENGLISH
3.9 - SWING OPERATION
a
,IWKHXQLWLVHTXLSSHGZLWKWKHÀDSSUHVVNH\³
B3
´WKHLFRQOLJKWVXSDQGWKHÀDSZLOOVWDUWWRVZLQJ
Press key “
B3
´DJDLQWKHLFRQVZLWFKHVRIIDQGWKHÀDSZLOOVWRSVZLQJLQJDQGZLOOUHPDLQLQWKHSRVLWLRQ
reached at that moment.
,IWKHIDQLVVZLWFKHGRIIZKLOHWKHÀDSLVVHWWRVZLQJPRGHWKHVZLQJVWRSVDQGUHVWDUWVZKHQ
the fan is switched on again.
This function can only be activated/deactivated from the remote controller.
3.10 - SPECIAL FUNCTIONS
3.10.a -
Air sampling
In heating or cooling mode and with ambient temperature higher or lower than the desired value, the fan
is periodically powered for 1 minute at minimum speed.
This way, the system is able to adequately keep temperature in the room under control and to reactivate
faster in case of need.
This function is not active by default.
It is possible to activate it in the factory or through an authorized assistance centre.
3.10.b -
Commands lock
To lock the keys on board the machine, keep keys
“
”
(T1) pressed simultaneously for 5 seconds.
7KHDFWLYDWLRQRIWKHIXQFWLRQLVYHUL¿HGE\WKHYLVXDOL]DWLRQRI%/RQWKHGLVSOD\HYHU\WLPHDQ\NH\LV
pressed.
This function can only be activated/deactivated from board the machine.
3.11 - OPERATION WITH TIMER (DELAYED SWITCHING ON AND SWITCHING
OFF)
This mode allows to program the unit switching on and switching off
The delay time can be set, activated and cancelled from the remote controller.
3.11.a - Setting of the switching on timer from remote controller
a
. After switching on the unit, select the operating mode, desired tempera-
ture and fan speed with which the unit will reactivate at the programmed
switching on.
Then, set the machine to Stand-By mode.
b
. Press key “
B8
” to set the desired delay (from 1 to 24 hours) after which
WKHXQLWZLOOVZLWFKRQVWDUWLQJIURPWLPHUFRQ¿UPDWLRQ
c
. If no key is pressed within 5 seconds, the timer setting function will
end automatically.
d
. The remote controller display shows the countdown for switching on
while the display of the fan coil shows the message “tI”.
Once the set time passes, the unit will start with the last selected set-
tings.
Содержание Bi2 Series
Страница 2: ......
Страница 5: ...2 6 8 1 4 3 3 7 5 9 10 Min 20 Min 20 Min 400 B A Min 80 Min 400 Min 80 Min 400 1 2...
Страница 6: ...T T S S 2 1 4 3 6 5 7...
Страница 7: ...T S S v T S 9 8 10 17 15 16...
Страница 8: ...11 13 12 18 9 19 25 12 23 24...
Страница 9: ...14 15 26 26 7 7a 26 26a...
Страница 10: ...17 27 27 16 27a 27a 27a 17 17a 27 27b 17 27a...
Страница 11: ...18 28 19 29...
Страница 13: ...M M 230Vac 50Hz 20b 21...
Страница 14: ...23 22 40 41 41 41 40 40a 40a 42 40 42a 40a 41 41...
Страница 87: ......