background image

PWR-SWITCH

Operation Manual

Rev.1.0  July 2020

olimex.com

1

Содержание PWR-SWITCH

Страница 1: ...PWR SWITCH Operation Manual Rev 1 0 July 2020 olimex com 1 ...

Страница 2: ...Table of Contents What is PWR SWITCH 3 PWR SWITCH Features 4 How to use PWR SWITCH 5 Certificates 6 Revision History 9 2 ...

Страница 3: ...lated high voltage switch which could be controlled with small voltage controllers like Arduino ESP32 Raspberry Pi and etc similar devices or microcontrollers 3 GREEN status LED EU style power receptable 230VAC 16A Control line EU style power plug ...

Страница 4: ...cal motors cause sparkling when disconnected which wear the contacts very fast Mechanical number of open close operation 10 000 000 times Number of Switch on off under full electrical load 100 000 times Green LED status indicator Control line works with DC Voltage in range 3 24VDC Enclosure Material Fire retardant ABS V0 Color White Operating Temperature 0ºC 40ºC 32 F 104 F Humidity 5 90 RH Non co...

Страница 5: ...h Arduino you should connect the green termianl with to GND and the terminal with to Arduino D0 pin Here is the code to switch it on and off void setup pinMode D0 OUTPUT void loop digitalWrite D0 HIGH delay 1000 digitalWrite D1 LOW delay 10 The control line will work with any voltage from 3V up to 24V DC 5 ...

Страница 6: ...tification and passed these standards tests CE EMC EN 55032 2015 EN IEC 61000 3 2 2019 EN 61000 3 3 2013 A1 2019 EN 55035 2017 CE LVD EN 62368 1 2014 A11 2017 All tests are made in accredited laboratory and kept on file at Olimex Ltd 6 ...