background image

4. Mounting

2. Required Items

- Wireless Analog Input Module (WM-xxxx-003)

- External Power Source for Module (9-30 Vdc)

- Antenna for Gateway (Bulkhead, Omni, or Yagi)

- Antenna Cable (N to MMCX Connector)

- N to N Antenna Cable and Ligh�ng Arrestor

- External Enclosure for Module (NEMA)

- DIN Rail (35 mm)

- All-in-One Configura�on Cable (SX1000-CC2)

Technician’s Screwdriver (flathead)

- Screwdriver Set

Any other tools or equipment for proper installa�on

- BreeZ® Configura�on So�ware

- PC with

 

Microso� Windows® Vista or later

 

1 GHz or faster processor, 256 MB or more RAM

 

20 MB hard disk space or more,

 

USB port, Internet connec�on

 

CAUTION

: Field wiring connec�ons shall be made in accordance

              with Ar�cle 504 of the Na�onal Electrical Code, ANSI/NFPA70.

 CAUTION

: The Module must be installed within an enclosure

 

that requires a tool to access. This is to prevent inadvertent

disconnec�on of any of the power wiring, signal wiring or

communica�on cables.

ATTENTION

: Le Module doit être installé dans une enceinte qui nécessite

un ou�l d'accès. Ce est pour éviter toute déconnexion accidentelle de l'un

des câbles câblage de puissance, câblage ou de communica�on signaux.

 WARNING

: Ensure installa�on of the Module meets applicable

 

state and na�onal electrical code requirements. The installa�on

of the Base Unit

should only be performed by a qualified installer or a

factory representa�ve.

AVERTISSEMENT

: Veiller à l'installa�on de la passerelle répond Etat et

des exigences na�onales de code de l'électricité. L'installa�on de la

Module 

ne doit être effectuée par un installateur qualifié ou un

représentant de l'usine.

 WARNING

: To prevent igni�on of flammable or combus�ble

 

atmospheres, disconnect power before servicing.

AVERTISSEMENT

: Pour éviter l'inflamma�on d'atmosphères inflammables

ou combus�bles, débrancher l'alimenta�on avant l'entre�en.

 WARNING

: EXPLOSION HAZARD – Subs�tu�on of components

 

impair suitability for Zone 2.

AVERTISSEMENT

: RISQUE D'EXPLOSION - Le remplacement de composants

nuire à la conformité pour la Zone 2. 

 WARNING

: EXPLOSION HAZARD – Do not separate/disconnect

 

connectors when energized.

AVERTISSEMENT

: RISQUE D'EXPLOSION - Ne pas séparer / débrancher les

connecteurs lorsque excité. 

 WARNING

: EXPLOSION HAZARD – Do not service when an

 

explosive atmosphere is present.

AVERTISSEMENT

: RISQUE D'EXPLOSION - Ne pas service lorsque une

atmosphère explosive est présente.

 WARNING

: EXPLOSION HAZARD – Do not use reset switch in

 

hazardous area.

AVERTISSEMENT

: RISQUE D'EXPLOSION - Ne pas u�liser le commutateur

de réini�alisa�on en zone dangereuse.

1. Before You Begin

This guide provides basic informa�on to assist you in quickly

ge�ng started. Go to support.oleumtech.com to download the

full User Guide for detailed installa�on and other informa�on.

Quick Start Guide

Wireless Analog Input Module 

80-3124-001_D

1. Download and install latest BreeZ® So�ware to PC 

2. Create a BreeZ® Project File

3. Power up Module (9-30 Vdc) and wait un�l boot-up

     sequence is complete 

 

(LED will turn off once boot-up is complete)

4. Connect Module to PC using SX1000-CC2 cable

         Connect black USB connector to PC

         Connect black RJ45 connector to Module’s config port

5. Iden�fy and select COM Port in BreeZ®

 

3. 

Configuration Sequence 

6. Update Module with BreeZ® Project File 

May need to check “Device Manager” on PC

to iden�fy COM Port

1. Remove the two screws in the top plate and carefully 

     remove the cover. The two moun�ng holes slots should 

     be visible near the bo�om of the Wireless Mul�-I/O 

     Module.

2. Mount the Wireless Analog Input Module on a 32mm 

    (1.26 inch) DIN 1 or 35mm (1.38 inch) DIN 3 rail inside 

    enclosure in a 

suitable loca�on. Mount Module in a

    loca�on 

that allows access to connectors for easy

    installa�on and service.

5. Dimensions

1.4”

3.0”

3.8”

Wireless Analog Input Module

1

2

3

4

5

6

1

2

3

4

5

6

7

8

AVCC

AIN1

GND

AVCC

AIN2

GN

D

AVCC

AIN3

GND

AVCC

AIN4

GND

V+

GN

D