TS-5000_v01_UK with CE
1
English
INSTRUCTION
MANUAL
FOR
DIGITAL
THERMOSTAT
M
ODEL
:
TS-5000
Nr.
Code
Description
Setting
Information
Preset
1
LK1
Electronic lock (Lock 1)
0
~
200
Setting code to change setting for
SC and C-F (code 116)
0
2
SC
Calibration
-9.9
~+
9.9
0.0
3
C-F
Change the
℃
and
℉
0
~
1
℃
4
Lk2
Electronic lock (Lock 2)
0
~
200
Setting code to change setting for
P, I , D and AT (code 181)
0
5
P
Proportion area
0
~
999
Manual setting for P
80
6
I
Calculus time
0
~
999
Manual setting for I
80
7
d
Differential time
0
~
999
Manual setting for D
20
8
At
Auto Tune function
(self setting)
0
~
1
ON= Auto Tune Function for PID
OFF= Manual Function for PID
OFF
The sensor is NTC 5K
T
EMPERATURE SETTING
Press the ▲ or ▼ key enter the temperature setting, press the ▲ key to increase and press the ▼ key to
decrease the temperature. Press the SET key to save the value and get out of the temperature setting. If not
touched the key within 8 seconds the temperature setting is saved automatically and also returns to measure.
O
THER SETTINGS
When press the SET key the display shows LK1. This is the lock1 function. Enter number 116 and press SET
again. Now you can change the SC and C-F function. Press SET again to leave the programming.
Press the SET key for a longer time until the display shows LK2. This is the lock2 function. Enter number 181
and press SET again. Now you can change “P” , “I” , “D” , “AT”. Press SET again to leave programming.
P,
I,
D
AND
AT:
These functions can be used for more experienced users. Auto Tune is the automatic setting system to set the
P, I and D values for the best results for your situation. The green led on the display will blink when the AT is
working. After setting the best values it will install itself the new found P,I and D values.
H
OW TO CONNECT
?
Connect this thermostat as on the drawing below. It is important that this product is connected by somebody
with knowledge about electricity. In case you don’t have please ask a certified person!