OLBA TS-5000 Скачать руководство пользователя страница 1

 

 

TS-5000_v01_UK with CE 

 

 

                                                                                                                                                                          English 

INSTRUCTION

 

MANUAL

 

FOR

 

DIGITAL

 

THERMOSTAT

 

 

M

ODEL

:

 

TS-5000 

Nr.  

Code  

Description  

Setting  

Information  

Preset  

LK1 

Electronic lock (Lock 1) 

0

200 

Setting code to change setting for 
SC and C-F (code 116) 

SC 

Calibration 

-9.9

~+

9.9 

 

0.0 

C-F 

Change the 

 and 

 

0

 

 

Lk2 

Electronic lock (Lock 2) 

0

200 

Setting code to change setting for 
P, I , D and AT (code 181) 

Proportion area 

0

999 

Manual setting for P 

80 

Calculus time 

0

999 

Manual setting for I 

80 

Differential time 

0

999 

Manual setting for D 

20 

At 

Auto Tune function 

(self setting) 

0

ON= Auto Tune Function for PID 
OFF= Manual Function for PID 

OFF 

The sensor is NTC 5K 

T

EMPERATURE SETTING

 

Press the ▲ or ▼ key enter the temperature setting, press the ▲ key to increase and press the ▼ key to 
decrease the temperature. Press the SET key to save the value and get out of the temperature setting. If not 
touched the key within 8 seconds the temperature setting is saved automatically and also returns to measure.  

 
O

THER SETTINGS

 

When press the SET key the display shows LK1. This is the lock1 function. Enter number 116 and press SET 
again. Now you can change the SC and C-F function. Press SET again to leave the programming.  
Press the SET key for a longer time until the display shows LK2. This is the lock2 function. Enter number 181 
and press SET again. Now you can change “P” , “I” , “D” , “AT”. Press SET again to leave programming. 

P,

 

I,

 

D

 AND 

AT: 

These functions can be used for more experienced users. Auto Tune is the automatic setting system to set the 
P, I and D values for the best results for your situation. The green led on the display will blink when the AT is 
working. After setting the best values it will install itself the new found P,I and D values.  

H

OW TO CONNECT

Connect this thermostat as on the drawing below. It is important that this product is connected by somebody 
with knowledge about electricity. In case you don’t have please ask a certified person! 
 
 