SECTION 5 S, T, AND M FUNCTIONS
6.
STM Time Over Check Function
The duration of S, T, M cycle time is measured and if the measured time exceeds the parameter-set
cycle time, an alarm occurs.
6-1.
Check ON Conditions
•
The check function is set effective or ineffective according to the setting for a machine
parameter.
•
The check function is turned on and off using the following M codes.
6-2.
S, T, M Cycle Time Setting
Set, for the machine parameter, the allowable limit of cycle time when executing an S, T, and M
codes.
•
Parameter setting
M124 : STM time over check start
M125 : STM time over check end
Units
: 0.1 seconds
Maximum
setting
: 600 seconds