OKI Data Infotech Corporation CONFIDENTIAL
Chapter 2 Site preparation check
2-5
2.4
Electrical configuration
The electrical configuration to connect the Printer's power cord is shown below.
(1) Power specifications
The power specifications of the printer are shown below. Confirm that the primary-side power
also satisfy these specifications.
Power voltage:
120V AC ± 10% (for USA use)
230V AC ± 10% (for European use), single phase
Power frequency:
50/60 Hz ± 1Hz
Power consumption:
1450 W or less
Instantaneous interruption: 10 ms or less
Earth:
Grounding (with the ground resistance of 100 Ω or less)
Power plug:
NEMA 5-15P UL817, CSA C22.2 (for USA use)
CEE7/VII DIN VDE 0620-1, EN50075, IEC 60884-1
(For European use)
Power cable length:
3 m (118.11 inches)
Cautions
The earth is grounded exclusively for the signal wiring to prevent noise due to induction, etc., so do
not connect it with the one for power.