background image

I N S T R U C T I O N S

© 2015 OJ Electronics A/S

 

 1

Waterline Add-On Module

English

Product programme

WLM3-1AO   Add-On Module, 230 V

WLM3-3AO   Add-On Module, 24 V

System configuration 

A master is capable of controlling eight heating zones referred to as 

channel 1 to 8. This add on (AO) module adds another six outputs referred 

to as channel 9 to 14.

Connection of master and add-on module

Connect the AO module using the special cable included in the box. 

Connect mains voltage from a 230 V fused isolator.

System setup

For information on setting up the system, please refer to the Installation 

Manual supplied with the master. 

Maintenance

The unit is maintenance free.

Certifications

CE marking

OJ Electronics A/S hereby declares that the product conforms with the 

following Directives of the European Parliament and of the Council:

• CE marking: 1993/68/EEC

• LVD - low voltage directive: 2006/95/EC

• EMC - electromagnetic compatibility: 2004/108/EC

•  RoHS - restriction on the use of certain hazardous substances: 2011/65/

EU

• WEEE - waste electrical and electronic equipment: 2012/19/EU

Applied standard(s)

EN 60730-1, EN 60730-2-9

Disposal and recycling

Recycling of packaging

Protect the environment by disposing of the packaging in accordance with 

local regulations for waste processing.

Disposal of the product

Equipment containing electrical components must not be 

disposed of together with domestic waste.

It must be collected separately along with other electrical 

and electronic waste according to local and currently valid 

legislation.

Technical Specifications

Purpose of control  . . . . . . . . . . . . . .Add-on module for controlling hydronic 

floor heating and cooling

Voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V AC ±10%, 50 Hz

Output for thermal actuators  WLM3-1AO  . . . . . . . . . . . . . . . . . . 230 V AC

 WLM3-3AO  . . . . . . . . . . . . . . . . . . . 24 V AC

67415 02/15 (HKT)

•  English

•  Polski

•  Norsk

•  Deutsch

Ambient operating temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0/+40°C

Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 outputs for thermal actuators

Control panel  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 LED indicates power

6 LEDs indicate thermal actuators

Relay output . . . . . . . . . . . . . . . . . . . . . . . . .Sec. pump, max. 5 A, 230 V AC

Mounting method . . . . . . . . . . . . . . . . . . . . . . . . For mounting direct on wall

Type of action. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Type 1.B.

Control pollution degree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Software class  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A

Overvoltage category . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .III

Rated impulse voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 kV

Ball pressure temperature  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125°C

SELV limit, realised   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V DC

Enclosure rating  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 21

Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H/130, W/315, D/53 mm

OJ ELECTRONICS A/S

Stenager 13B · DK-6400 Sønderborg · Denmark

Tel. +45 73 12 13 14 · Fax +45 73 12 13 13

[email protected] · www.ojelectronics.com

BR1025A16a

© 2015 OJ Electronic  

A/

S

WLM3-BA/FS Master 

WLM3-AO Module 

 AO Module Cable

 

Fig. 1

     

BR1025A16a

Отзывы: