5.4.5 Position valve settings: settings for control valves
This view allows you to configure the settings for control valves associated with heating
circuits and the domestic hot water temperature limiter accessory. Each of these has
two different settings views.
Position valve settings ver. 1
If the temperature in the lower section of the storage tank is lower than heating circuit
temperature, the storage tank’s temperature will be automatically increased to heating
circuit temperature plus an offset (
Boiler temperature deviation from heating curve
).
The adjustment range for the offset is 0–10 °C, factory setting: 10 °C.
Settings view
Position valve HC1 ver. 1
The following settings can be configured for each of the heating circuits:
50 (70)
M8011 2204EN