1.4 Transportation and storage
Storage
Store the unit upright in a warm, dry place. Protect the device against water and dust.
Do not stack goods on the unit.
Transportation
Transport the unit upright and protected against water and dust. Do not stack goods
on the unit. Use only safe lifting and handling methods when moving or lifting the
unit. After lifting, lower the unit carefully down onto the floor. Hard impacts can cause
equipment damage.
The compressor unit can be tilted up to 45 degrees from horizontal.
If the unit is tilted beyond 45 degrees, the compressor may not receive proper
lubrication at startup. As a result, the compressor may become damaged.
● If the unit has been accidentally tilted beyond 45 degrees, leave the unit in vertical
position for at least three hours before starting the compressor.
Lifting units equipped with a built-in DHW tank
Do not lift or move the unit with the domestic hot water tank filled.
Do not lift the heat pump from the bottom of the compressor unit. Lift the
unit by the frame.
● The unit’s exterior panels may be removed to make it easier to carry and move the
unit.
● The unit can be carried short distances by the side bars.
● If necessary, the compressor unit can be detached from the frame of the heat pump
before carrying or tilting the unit.
● If you need to tilt the heat pump beyond 45 degrees, remove the compressor unit.
1.5 Scope of delivery
Equipment and components
Item
PCS
Item code
Description
Installation and
commissioning manual
1
This manual
Operation manual
1
M8004
Quick guide
1
M8007
Electrical drawing
1
34793610
Diagram 110974
6 (59)
M8006 2314EN