フィルタ軸の切込みを巻取りケースの回転軸に合わせ下図の向きになるようにセットしてください。

 

Align the slits of filter core with the rotary axis of Winding Case and set the filter so it is directed as illustrated 
below. 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

※センサー等がある場合はセンサー
と開口部との間にフィルタを通すよう
にしてください。

 

*If there is a sensor and the like 
above the suction port, pass the filter 
in between. 
 

巻取りケース

 

Winding case 

フィルタケース

 

Filter case 

回転軸

  Rotary axis 

切込みを合わせる

 

Align the slits on the rotary axis 

Содержание KURU OKF-AOC320-AW

Страница 1: ...ual Thank you for purchasing this product Please read through this brochure prior to use and keep at hand thereafter for future reference Contents Safety precautions 2 Part names 4 Installation 5 Oper...

Страница 2: ...et Stay by people with medical electronics like pacemakers Be careful not put it closer to such people Caution Do not put your fingers or foreign substances into the rotating part Installation and fil...

Страница 3: ...ed for installation of the product must be done only by specialists Improper installation may result in electrical shocks or fires Make sure that there is no damage on the package on delivery Please r...

Страница 4: ...agnet Stay Option Winding case Winding case rear view Filter Operation panel Control part Winding unit Fuse holder 250V 2A Main power switch Power cable Slot Clamp Stay Option Knob Rubber pad Magnet F...

Страница 5: ...to use either the optional Clamp Stay or Magnet Stay Failure to this can lead to falling accident of the product 700mm p 28 p 28 In case the distance between the Filter case the Winding part is over...

Страница 6: ...Filter case is fitted with Magnet Stay Lower side Winding case is fitted with Clamp Stay D D Upper side Winding case is fitted with Magnet Stay Lower side Filter case is fitted with Clamp Stay Magnet...

Страница 7: ...trudes from the filter by approx 40mm on right side and approx 80mm on left side Any physical interference within it may prevent the product from being fitted properly Installation of Filter case and...

Страница 8: ...ded in width For attaching Clamp Stay adjust its width to fit the size of installed objects If the knob is turned too much it can drop off from the Clamp Stay Position the Clamp Stay on the mounting s...

Страница 9: ...ng to 1 Different combinations of fittings in the paragraph Installation in page 5 3 Mounting with Magnet Stay Remove dirt and oil from the mounting surface using a cleaning agent If oil remains magne...

Страница 10: ...can result in breakdown of the motor In case the installed object has been fitted with its manufacturer s original filter be sure to remove it before installing this product Do not use this product pl...

Страница 11: ...e Filter Case and the Winding Case when attaching them Remove the wing screw and the square nut from the Clamp Stay Attach the provided aluminum filter guide pipe To fix the pipe inside the Clamp Stay...

Страница 12: ...rs on both ends in the Filter Case in the direction as shown below Fix the Filter Case upper side and the Winding Case lower side with respective wing screws and square nuts Aluminum pipe Temporarily...

Страница 13: ...wn on the roller align its slits on the rotary core on the other end to set in Aluminum pipe Align the slits on the rotary axis Filter core Cross section Roller If there is a sensor and the like above...

Страница 14: ...ilter is set appropriately M4 Make sure that the filter is not inclined If not loosen the M4 screw of either of the Winding Case or the Filter Case to adjust its position so the filter can go straight...

Страница 15: ...on port In case anther filter has already been there remove it For attaching to the Magnet Stays see page 9 Fit the filter core into the holders on both ends in the Filter Case in the direction as sho...

Страница 16: ...rotary axis of Winding Case and set the filter so it is directed as illustrated below If there is a sensor and the like above the suction port pass the filter in between Winding case Filter case Rotar...

Страница 17: ...t attached pipe on the slits of Magnet Stay with pressing against the filter and secure the wing screw Aluminum pipe Move the aluminum pipe backward and then downward to secure Make sure that the filt...

Страница 18: ...llation type C p 8 p 10 Attach the Filter Case with the Magnet Stay on the upper side and the Winding Case with the Clamp Stay on the lower side of the suction port In case anther filter has already b...

Страница 19: ...h attaching the square nut into the pipe through one of the two square holes of the Clamp Stay Fit the filter core into the holders on both ends in the Filter Case in the direction as shown below Brin...

Страница 20: ...e slits of filter core with the rotary axis of Winding Case and set the filter so it is directed as illustrated below Roller Filter core Cross section If there is a sensor and the like above the sucti...

Страница 21: ...gnet Stay with pressing against the filter and secure the wing screw Loosen the temporarily fixed wing screw and move the aluminum pipe backward Make sure the filter is set appropriately Make sure tha...

Страница 22: ...allation type D p 6 p 8 Attach the Winding Case with the Magnet Stay on the upper side and the Filter Case with the Clamp Stay on the lower side of the suction port In case anther filter has already b...

Страница 23: ...h attaching the square nut into the pipe through one of the two square holes of the Clamp Stay Fit the filter core into the holders on both ends in the Filter Case in the direction as shown below Brin...

Страница 24: ...illustrated below Attach the provided aluminum filter guide pipe on Magnet Stay Hook the wing screw and square nut attached pipe on the slits of Magnet Stay with pressing against the filter and secur...

Страница 25: ...M4 Make sure that the filter is not inclined If not loosen the M4 screw of either of the Winding Case or the Filter Case to adjust its position so the filter can go straight Aluminum pipe Winding cas...

Страница 26: ...e is shown in the following table Lighting behavior State Off Off Power is off Lighting On Power is on stand by Lighting On Power is on motor is running To turn power off On Off 3 Hold down the On Off...

Страница 27: ...5mm 90 3 90 days approx 3 months 8 63 5mm 60 2 60 days approx 2 months 9 127 0mm 30 1 30 days approx 1 month The above values are shown as a guide and subject to change in practical use Manual windin...

Страница 28: ...p 18 1 If the filter is caked with oil or stuck on the opening of the object peel off dirt by hand and wind up the filter until its clean part appears In case the same warning recurs frequently chang...

Страница 29: ...ed fuse blows again when reinputting power please contact us d Please contact us Magnets do not work The mounting surface is dirty The mounting surface is not flat The mounting surface is not magnetic...

Страница 30: ...Off button to turn power off Prepare a new filter Slide the aluminum pipes of the Winding Case and the Filter Case forward and loosely fasten there Note There is a risk that the aluminum pipe can dro...

Страница 31: ...filter amount Without resetting process filter winding will not be done properly 2 B Filter replacement for Comb type B On Off Off Hold down the On Off button to turn power off Prepare a new filter Lo...

Страница 32: ...r lights and then goes off to reset the remaining filter amount Without resetting process filter winding will not be done properly 3 C Filter replacement for Comb type C On Off Off Hold down the On O...

Страница 33: ...t the filter core of the Filter Case so it passes behind the aluminum pipes p 18 C Attach a new filter For attachment refer to the instruction in page 18 Set Reset r On completion of work hold down th...

Страница 34: ...uminum pipe forward and loosely fasten there Take out the filter core from the Filter Case by pulling it forward Compress the spring and release the filter in the Winding Case by pushing the filter co...

Страница 35: ...ilter winding will not be done properly Waste disposal KURU KURU FILTER basically consists of the following parts For proper disposal of these parts observe your local regulations applicable to each m...

Страница 36: ...free from condensation Function Winding length setting Filter replacement warning Winding error warning Winding overload warning Power connection 3 2m 0 75sq 3 core power cable 2m long Fuse B 5 2 20mm...

Страница 37: ...rew fixing with 4 M4 screws Paint color Black Weight Approx 1 0kg Accessories M5 65 Wing bolt M5 65 2 M5 Square nut M5 2 Magnet Stay data Model OKF MS01 KURUKURU Filter models to apply OKF AOC320 AW O...

Страница 38: ...Outline drawing OKF AOC320 AW OKF AOC430 AW OKF AOC520 AW OKF CS320 01 OKF CS430 01 OKF CS520 01...

Страница 39: ...OKF MS01 Space required for installation by Clamp Stay...

Страница 40: ...e possible combinations of this product and installed objects In case there is any concern about damaging the installed object please verify by yourself before using this product We are not responsibl...