255571 (Rev. 1) 01/20
SELECTORR
®
Series Claw Vacuum Pump
C30 Model
Installation & Operation Manual
Страница 1: ...255571 Rev 1 01 20 SELECTORR Series Claw Vacuum Pump C30 Model Installation Operation Manual...
Страница 2: ...1 4 Power Requirements 4 1 5 Vacuum Connections 5 1 6 Oil Filling on Gear Box 5 2 0 SAFETY 6 2 1 General Notices 6 2 2 Warning Labels and Explanation 6 2 3 Location of Labels 6 3 0 OPERATION 7 3 1 Sta...
Страница 3: ...luminum check valve for anti suck back and inlet filter flanged can be installed separately The C30 is well suited to use with Variable Frequency Controlled Drives for energy savings 1 2 Unpacking Sto...
Страница 4: ...ferent please contact Ohio Medical for motor and starter information Correct direction of rotation is marked by an arrow on the motor fan housing and is counterclockwise when looking at the motor from...
Страница 5: ...ines result in reduced pump capacity Pumps operating in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the suction...
Страница 6: ...ion Only authorized and trained operators should operate the vacuum pump If the pump is not properly working it should be stopped immediately Ohio Medical shall have no liability for any accident or f...
Страница 7: ...in failure of and severe damage to the machine Vacuum Regulator installed in inlet flange is set at maximum allowable vacuum at factory and a desired vacuum level to below the maximum level can be ac...
Страница 8: ...Gear Box Oil 4 1 1 Oil Level Check the oil level on a monthly basis Under normal circumstances it should not be necessary to add oil between oil changes A significant drop in oil level means there is...
Страница 9: ...the pump or system 5 4 Problem The pump is extremely noisy 5 4 1 Possible Cause Contamination of the claws or chamber Remedy Clean the pumping chamber and the claws 5 4 2 Possible Cause Coupling inser...
Страница 10: ...agent for service or exchange program 6 0 TECHNICAL DATA VACUUM APPLICATION SPECIFICATIONS Model C30 CFM 60 HZ 670 50 HZ 558 HP 60 Hz 30 50 HZ 25 RPM 60 Hz 3450 2850 50 HZ dB A Max 3 tolerance 60 Hz...
Страница 11: ...11 255571 Rev 1 01 20 C30 CLAW VACUUM PUMP WITH 30 HP NEMA 286TC MOTOR...
Страница 12: ...12 255571 Rev 1 01 20 ASS y DRAWING VCX 1005 ASSEMBLY DRAWING C30...
Страница 13: ...ld Cover side Right 1 99 Accoustic Mat for Shield Cover side left 1 100 Coupling Pump Side 1 101 Insert Coupling 1 102 Coupling Motor Side 1 103 Fan New 1 104 Flange Adapter fan housing side NEMA 1 10...
Страница 14: ...ent contains information that is proprietary and confidential to Ohio Medical LLC Use of this information is under license from Ohio Medical LLC Any use other than that authorized by Ohio Medical LLC...