xxxxxx(06/06)1.0
RS Series
Operator Manual
GB
Страница 1: ...xxxxxx 06 06 1 0 RS Series Operator Manual GB...
Страница 2: ...uct OHAUS CORPORATION RESERVES THE RIGHT TO MAKE REFINEMENTS OR CHANGES WITHOUT NOTICE Ohaus Corporation 2006 No part of this manual may be reproduced or transmitted in any form or by any means electr...
Страница 3: ...ANY INTERNAL ELECTRONIC COMPONENTS OR INTERCONNECTING WIRING BETWEEN ELECTRONIC EQUIPMENT ALWAYS REMOVE POWER AND WAIT AT LEAST THIRTY 30 SECONDS BEFORE ANY CONNECTIONS OR DISCONNECTIONS ARE MADE FAI...
Страница 4: ...6 32 18 Czechia 48 34 51 03 20 Denmark 54 34 57 45 23 France 41 20 51 00 19 Finland 59 48 70 05 25 Germany 47 00 55 00 20 Greece 34 48 41 45 15 Hungary 45 45 48 35 19 Ireland 51 05 55 05 22 Iceland 63...
Страница 5: ...g Mode 7 3 4 1 20 Function Keys 7 3 4 2 30 Preset Keys 7 4 Operation 8 4 1 Zero 8 4 2 Tare 8 4 2 1 Pushbutton Tare 8 4 2 2 Input Preset Tare Manually 8 4 2 3 Tare Display 8 4 3 Item Management Levels...
Страница 6: ...18 4 12 Backlight 18 5 Setup 19 5 1 Key Function in Setup Mode 19 5 2 Quick Key on the fly function 19 5 2 1 Quick Key Location 19 5 2 2 Function of the Quick Key 19 5 3 Acess to Setup Mode 20 5 3 1...
Страница 7: ...50 o C Power supply 100 240V universal AC power Battery option 12V 5Ah lead acid rechargeable battery Interface 1 port for cash drawer 2 RS 232 for PC or scanner 1 USB option 1 Ethernet option PLU qu...
Страница 8: ...th scanner COM2 male DB9 RS 232 to connect with PC Cash Drawer RJ11 to connect with cash drawer Ethernet port RJ45 network option USB to connect with PC or scanner option The requirement on the cash d...
Страница 9: ...e then X to test paper The procedures to install label are as follows 1 Push the switch of the printer door backward to the customer side with thumb the door will open 2 Open the door wider 3 Take the...
Страница 10: ...used properly it can withstand 300 cycles The new battery can provided about 30 hours work after fully charge A fully charged battery normally lasts 12 hours The charge time will be shorter if the ba...
Страница 11: ...8888 888 888888888888 All cursors Step2 From top to bottom it displays the part number of the software version number country code and GEO value 179403 1 0 EU 20 Step3 Ready to weigh 0 000 0 00 0 00 V...
Страница 12: ...unit price tare or PLU will not disappear when items are removed or accumulated into total 100g The weight unit of the price is 100g The current power is AC Lit The power is battery Flash and lit Cha...
Страница 13: ...the following key to complete function written on its top right corner Key Shift function Function Disc C Time key Access to or exit date time showing mode LS Large item key Access to large weight in...
Страница 14: ...Manually Procedure Description Key operation Display on 1st line Display on 2nd line Display on 3rd line Display on the bottom line Lit cursor Step1 Gross weight should be zero 0 000 0 00 0 00 V1 tic...
Страница 15: ...0 000 0 00 0 00 V234 ticket When scale is turned off all vendors will automatically be logged out 4 5 Recall PLU item information or Input Unit Price and Compute Price There are 3 ways to recall PLU...
Страница 16: ...x Step4 Calculate the total price of 3 items 3 Cn 3 2 00 6 00 x Recall information with scanner e g recall the information of one bag of wash powder its PLU is 8 and item 13 digits is printed on the...
Страница 17: ...to weighing mode Input PLU number Press tare Press key C The format sample of the ticket is listed below 4 6 2 Multi payment Way Enable multi payment way first as follows Procedure Description Key op...
Страница 18: ...y on 2nd line Display on 3rd line Display On the bottom line Have done 2 transactions V1 0 000 0 00 0 00 V1 P2 A 11 62 next No matter change function is enabled or not press voucher key to get into to...
Страница 19: ...cket In setting item 206 printing a copy of ticket can be set to be enabled In this case after printing the ticket press again a copy of the ticket will be printed and characters COPY will be shown on...
Страница 20: ...ket Step2 Recall PLU1 1 0 000 9 80 0 00 PLU 1 Step3 Put item on the platter 0 500 9 80 4 90 PLU 1 Two transactions were finished 0 500 0 00 0 00 V1 P2 A 11 62 next Default to cancel the last transacti...
Страница 21: ...1 0 For example All related setting parameters are default and one customer will buy two items PLU1 In S116 the set discount rate is 12 unit price of PLU is 9 80 so the discounted unit price is 8 62 P...
Страница 22: ...e are 3 available results depending setting item 214 1 When select parameter 0 Print label but the transaction will not be accumulated Step4 Print label V1 0 500 9 80 4 90 PLU 1 2 When select paramete...
Страница 23: ...total 5 00 4 8 3 Prepack in Label Printing Mode To by weight type PLU prepack operation is as follows Procedure Description Key operation Display on 1st line Display on 2nd line Display on 3rd line Di...
Страница 24: ...e is kg only no 100g even 100g can be shown 4 11 Show Data and Time Sleep mode If there is no key operation or weight change for about 3 minutes the scale will go to sleep mode At this time the time a...
Страница 25: ...ce Get the weight or go to the next line of the text Go to the last line of the text 5 2 Quick Key on the fly function 5 2 1 Quick Key Location Quick keys are preseted in the left 30 keys The location...
Страница 26: ...tup quick key or printing quick key and scale will access the related setup item directly 5 3 Acess to Setup Mode Procedure Description Key operation Display on 1st line Display on 2nd line Display on...
Страница 27: ...Set which items of PLU are visible 104 Group edit Edit group information 105 Vendor edit Edit vendor information 106 Date time Edit date and time 107 Shop edit Edit store name 108 Scale no Edit scale...
Страница 28: ...ep13 Please insert description L 1 Step14 Insert description Apple A p p l e S 6 Apple Step15 Select price type By Weight Step16 Select by count price type T By count Step17 Please insert unit price 0...
Страница 29: ...indicate the PLU has been preset 0 000 0 00 0 00 V1 ticket L 1 means 1st level PLU L 2 means 2nd level PLU If PLU number is 0 then no PLU is in this preset key Recall PLU Press a preset key to recall...
Страница 30: ...an be enabled or disabled through the setting in setting item 410 Edit group e g Group Description Tax 8 FOOD 6 00 Procedure Description Key operation Display on 1st line Display on 2nd line Display o...
Страница 31: ...t one 2 Vendor no Step10 Step11 Exit and go to next item MODE 106 Data time Printed edited vendor information Vendor List Scale No 1 2005 3 12 08 30 00 Name 1 Susan 2 Mary End 5 4 1 6 Edit Data and Ti...
Страница 32: ...Display on the bottom line Lit cursor Step1 In setup mode GR XX is shown e g Gr 01 Gr 01 Info input Step2 Get to setting 108 1 0 8 S 108 Scale no Step3 The default No is 1 S 108 1 Scale no Step4 Inse...
Страница 33: ...he bottom line Lit Cursor Step1 In setup mode GR XX is shown e g Gr 01 Gr 01 Info Input Step2 Get to setting 111 1 1 1 S 111 Tare edit Step3 Default to edit tare 1 S 111 TARE 1 Tare no Step4 Edit tare...
Страница 34: ...ep6 Right shift of A 2 bites S 112 Bar 1 2 A shift Step7 Left shift of B 1 bite S 112 Bar 1 1 B shift Step8 Check sum type 1 1 normal 2 reverse S 112 Bar 1 1 C parity Step9 Print and edit next one S 1...
Страница 35: ...nd 5 4 1 14 Update Stock 114 E g One store stocks the following goods in the morning and wants to insert the data into scale and clear all stock before doing so PLU Description Weight kg Quantity PCS...
Страница 36: ...t PLU PLU 1 20 PLU 1 0 Step5 Insert the actual quantity 20 2 0 20 PLU 1 20 Step6 Default is to edit next PLU insert PLU 3 3 0 950 PLU 3 0 000 Step7 Please insert the weight of PLU 3 0 000 0 950 PLU 2...
Страница 37: ...t Step16 Insert discount percentage 12 1 2 S 116 12 Percent Step17 Back to last level S 116 All items Step18 Discount to some group T S 116 Group Step19 Edit the discount of group1 S 116 Grp 1 Insert...
Страница 38: ...tep1 In setup mode GR XX is shown e g Gr 01 Gr 01 Info input Step2 Access to production date edit 1 2 1 S 121 Product date Step3 Show current date S 121 05 08 12 Current 0 Step4 The production date is...
Страница 39: ...re fixed in scale formats from 1 to 10 are free formats can be downloaded from PC Available parameters are 1 10 or 101 110 105 214 Reaction when press vendor key in label printing mode Act to v1 Print...
Страница 40: ...Select to delete T S 302 Sure yes Step7 2 means there are 2 groups from group 1 to group 8 S 302 Del 2 Step8 Edit again S 302 Grp 1 Del From Step9 Exit and go to next item MODE S 303 Del report Notic...
Страница 41: ...d line Display on 3rd line Display on the bottom line Lit cursor Step1 In setup mode GR XX is shown e g Gr 01 Gr 01 Info input Step2 Access to setting 306 to get PID or input LID 3 0 6 S 306 PID LID S...
Страница 42: ...permit Disabled no VAT 1 411 Clear unit price tare or PLU automatically when vendor key is pressed Tare P clear Clear Clear auto Don t clear Clear manual 0 412 Sleep when no weight change and key oper...
Страница 43: ...ed Speed normal 1 fast 2 very fast 1 Speed fast 2 Speed faster 1 439 Print contrast contrast Lightest Contrast 0 8 1 8 become heavier from 1 to 8 Contrast 1 8 4 440 1st day of the week First day typ M...
Страница 44: ...n Display on 1st line Display on 2nd line Display On 3rd line Display on the bottom line Lit cursor Step1 In setting mode GR XX is shown e g Gr 01 Gr 01 Info input Step2 Access to sales report setting...
Страница 45: ...e by one Step7 Default is not to print report S 616 Not Print Step8 Don t print and go to next item S 617 Promote rpt When printing combination report all combined reports will be printed at one time...
Страница 46: ...ep 2 Step 1 Step 1 Step 1 Step 1 Today The beginning PLU From plu no All PLUs All PLU Step 2 All PLU PLU range The end PLU to plu no 1 The beginning group From grp no All groups All groups Step 2 Step...
Страница 47: ...Step1 In setup mode GR XX is shown e g Gr 01 Gr 01 Info input Step2 Access to setting item 702 Ethernet setting 7 0 2 S 702 Ethernet Step3 Default is host S 702 Host Step4 Alternative is slaver T S 7...
Страница 48: ...the second time is not the same as that inserted the 1st time then input 1 999999 will be displayed for a while for requirement again If you don t insert anything when new password is required and pr...
Страница 49: ...E S 801 PW manager means add authority means delete authority all means all groups except group 5 E g 1 106 means add authority to edit all setting items in group1except item 106 If inputted data is n...
Страница 50: ...GHT AGAIN The weight does not change before accumulation WT TOO SMALL The weight is less than 20e when printing label or accumulation Wt too heavy The weight on the platter is more than full capacity...
Страница 51: ...1 RS Series with the Ethernet Port 2 Units 2 Cross Cable 1 Piece Pay attention please there are two types of the Net Cable the one is direct cable and another is cross cable Please check the cable typ...
Страница 52: ...n will show Update Data meanwhile the scale B slave scale is copying the data from the scale A master scale Please make sure that the communication is running smoothly at this moment especially do not...
Страница 53: ...ation under the FV Function Basic Business As we said at the beginning of this appendix RS Series FV function will bring out a fire new experience when you use it Please enjoy it along with our follow...
Страница 54: ...Real time 103 PLU content Unavailable N A 104 Group edit Available Real time 105 Vendor edit Available Real time 106 Date time Available Real time 107 Shop edit Available Real time 108 Scale no Unavai...
Страница 55: ...ture List Menu Description FV Available Data Update Method 401 Restore default Unavailable N A 402 Recall PLU by PLU or item Available Real time 403 Way to recall PLU Available Real time 404 Print edi...
Страница 56: ...ble N A 438 Printing speed Unavailable N A 439 Print contrast Unavailable N A 440 1st day of the week Unavailable N A 441 Filter strength Unavailable N A 442 ECR checkout way Available Real time 443 M...
Страница 57: ...0 V1 ticket 3 Press basket memory key V V 0 000 0 00 0 00 V1 ticket net 4 Print a ticket for basket 0 000 0 00 0 00 Pt 0 200 net 5 Remove the basket 0 000 0 00 0 00 V1 ticket BN will be as the ID code...
Страница 58: ...tare The basket tare priors the preset tare called by PLU Successive basket recall is possible 1 2 3 Basket Report At the end of the day it should be possible to receive a list of non used recalled ba...
Страница 59: ...TM 0 000 0 00 0 00 Tare M input Step3 Input the tare value 2 0 0 0 000 0 00 0 00 TM 0 200kg Step4 Press T to confirm T 0 200 0 00 0 00 Pt 0 200 net Step5 Remove all items on the platter and press T to...
Страница 60: ...orme s ou au x document s normatif s Al que se refiere esta declaraci n es conforme a la s norma s u otro s documento s normativo s Waarnaar deze verklaring verwijst aan de volende norm en of richtlij...
Страница 61: ...structions 55 Important notice for verified weighing instruments in EC countries The application of the Green M indicates that the non automatic weighing instrument has been verified at the place of m...
Страница 62: ...ulations at the collecting point specified for electrical and electronic equipment If you have any questions please contact the responsible authority or the distributor from which you purchased this d...