Страница 1: ...Adventurer Pro Balances Instruction Manual...

Страница 2: ...n Pine Brook NJ USA Date March 6 2003 Marking Directive Standard 73 23 EEC EN61010 1 2001 Electrical equipment for use Safety requirements for electrical within specified voltage limits equipment for...

Страница 3: ...ect the interference at his own expense This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada These products also...

Страница 4: ...of Controls EN 6 3 2 Control Functions EN 8 3 3 Basic Operation EN 9 3 3 1 Zeroing EN 9 3 3 2 Taring EN 9 3 3 3 Changing Units of Measure EN 9 3 3 4 Changing Application modes EN 9 3 3 5 Printing Data...

Страница 5: ...26 3 8 Legal for Trade LFT EN 26 3 9 Sealing Access to the Balance Settings EN 26 3 10 Printing Data EN 27 4 MAINTENANCE EN 28 4 1 Calibration EN 28 4 2 Cleaning EN 28 4 3 Troubleshooting EN 28 4 4 E...

Страница 6: ...ry or AC Adapter operation AC Adapter included Weighing Counting Percent Check Weighing Animal and Totalize application modes In use cover RS232 interface Integral security bracket Weigh below hook Th...

Страница 7: ...ackaging to ensure safe transport of the product 2 2 Installing Components Remove the cone cover from the top of the balance and store it for future use Refer to the illustrations below and install th...

Страница 8: ...e Menu Cal button until MENU is displayed then release the button CALIBRATE blinking is displayed Press the Yes button to enter calibration menu Press the Yes button to initiate span calibration Press...

Страница 9: ...Function 1 Buttons 8 Leveling feet 2 Display 9 Power connector 3 Platform 10 COM1 port 4 Type Label 11 Lock release button 5 Data Label 12 Security bracket 6 Battery compartment 13 COM2 port optional...

Страница 10: ...r 11 Tael Tola Tical unit indicator 12 Percent indicator 13 14 Kilogram indicaton 15 Pennyweight indicator No Description 16 Memory indicator 17 Newton indicator 17 20 Grain indicator 18 Battery charg...

Страница 11: ...sets zero Off Turns balance off Yes Accepts the current blinking setting on the display Print Sends current display value to the serial interface Unit Change weighing unit No Rejects the current blink...

Страница 12: ...lly tared and Net weight is displayed The Tare value is cleared automatically when the container is removed from the pan Preset Tare A preset tare value may be entered using the xT command in the comm...

Страница 13: ...eadout Mode Unit Print 1 Print 2 RS232 1 RS232 2 GLP Data GLP Print Reset Lock Set End Lockout END 3 7 12 3 4 1 Menu Structure PRINT 1 3 7 6 Output When Stable GLP Tare Auto Print Content Num Only Hea...

Страница 14: ...d the Menu button until MENU appears on the primary display Release the button and the first sub menu appears on the secondary display blinking Note A blinking display in the menu indicates a choice m...

Страница 15: ...nabled Before using any other units of measure they must be turned on in the Unit menu 3 5 2 Parts Counting Enter this mode to count samples of uniform weight Refer to paragraph 3 3 4 to enable Parts...

Страница 16: ...on button to accept The primary display will now indicate the number of parts The weight is shown on the secondary display Pressing the Function button momentarily displays the APW on the secondary di...

Страница 17: ...NT is shown on the secondary display 3 5 4 Check Weighing Enter this mode to compare the weight of a sample against target limits Refer to paragraph 3 4 3 to enable Check Weighing USE The secondary di...

Страница 18: ...gins Checkweighing Place the sample on the pan The UNDER ACCEPT OVER status is shown on the primary display while the actual weight of the item is shown on the secondary display 3 5 4 Check Weighing C...

Страница 19: ...e the animal is on the pan the primary display shows the actual weight and the secondary display alternates between ANIMAL and CLEAR PAN The balance returns to the Ready condition when the animal is r...

Страница 20: ...button until TOTALIZE is shown on the secondary display 3 5 6 Totalize Cont 3 6 Additional Features 3 6 1 Weigh Below The Adventurer Pro balance is equipped with a weigh below hook NOTE Before turnin...

Страница 21: ...e LCD backlight is normally off to conserve power The backlight turns on when the display becomes unstable or when a button is pressed The backlight turns off 5 seconds after the display becomes stabl...

Страница 22: ...ge Three weight values are used zero a weight value at or near the midpoint of the balance s weighing range and a weight at or near the balance s specified capacity Calibration Masses Before beginning...

Страница 23: ...f Auto Tare On Off Auto Off Off 1 2 5 min Back Light On Off End Setup Legal Trade When set On the balance operates in compliance with Weights and Measures regulations Auto Tare When set On the balance...

Страница 24: ...lize On Off End Mode Weigh Allows setting the weighing mode On or Off Count Allows setting the counting mode On or Off If Count is set On APW optimize can be set On or Off Percent Allows setting the p...

Страница 25: ...s button to advance to the Print 1 submenu Press No to return to the first available unit PRINT 1 Output When Stable On Off GLP Tare On Off Auto PrintOff Cont Interval When Stable 1 3600 seconds Stabl...

Страница 26: ...computer RS232 1 Power On Off Baud 600 2400 19200 Parity 7 Even 7 Odd 7 No Par 8 No Parity Handshake Off XONXOFF Hardware End RS1 RS232 2 contains an identical menu and is available when the optional...

Страница 27: ...Adjust Enter an adjustment value from 60 to 60 seconds per day Date Set the date type M D Y D M Y Y M D M Y D Y D M D Y M and the actual date End GLP Data Press the Yes button to advance to the GLP P...

Страница 28: ...Yes to return the menu items in all sub menus to their factory settings End Reset Press the Yes button to advance to the Lockout menu Press the No button to return to Setup 3 7 11 Lockout Use this sub...

Страница 29: ...following conditions apply The CALIBRATION menu is hidden The LEGAL TRADE menu item is hidden The AUTO ZERO menu item setting is set to 0 5d and locked The OutPUt WHENSTABLE menu item setting is set...

Страница 30: ...34567 If GLP SET Balance ID is ON USER ID ABCDEFGHIJ If GLP SET User ID is ON PROJ ID 1234567890 If GLP SET Proj ID is ON Name If GLP SET Name is ON If a tare value is entered these three items are pr...

Страница 31: ...FT set to on Turn LFT off Error code is displayed Causes vary Refer to the Error Code table and take appropriate action 4 MAINTENANCE 4 1 Calibration Periodically verify calibration by placing an accu...

Страница 32: ...4 Cable DB9M SF42 Printer 80500571 Cable DB9M Apple 80500562 SF42 Printer SF42 Calibration Weights ASTM Class 2 50g 49054 12 100g 49015 12 200g 49025 12 400g 49045 12 1000g 49016 12 2000g 49026 12 400...

Страница 33: ...bility is assured at ambient temperatures between 5 and 40 C Power AC adapter To national standard as per list in Section 4 6 Balance power input 6 14 5 VAC 50 60Hz 4VA or 7 20VDC 4W Batteries 4 x AA...

Страница 34: ...Drawings On Zero Of f Print Unit Function Mode Tare Menu C al Yes No Back Exi t 70 On Zero Off Print Unit Function Mode Tare Menu Cal Yes No Back Exit On Zero Of f Print Uni t Function M ode Tare M e...

Страница 35: ...l Baht Mesghal Tola Custom Application Modes Weighing Animal Weighing Parts Counting Percent Weighing Check Weighing Totalize Tare Range To Capacity by Subtraction Stabilization Time s 2 5 1 5 3 3 2 2...

Страница 36: ...0 05 Newton 0 50014 x 0 00001 2 0594 x 0 0001 4 0207 x 0 0001 7 9434 x 0 0001 20 594 x 0 001 ounce 1 79895 x 0 00005 7 4075 x 0 0005 14 4625 x 0 0005 28 5720 x 0 0005 74 075 x 0 005 ounce troy 1 63970...

Страница 37: ...m momme 1093 35 x 0 05 2160 00 x0 05 Newton 40 207 x 0 001 79 434 x 0 001 ounce 144 625 x 0 005 285 720 x 0 005 ounce troy 131 820 x 0 005 260 420 x 0 005 pennyweight 2636 4 x 0 1 5208 4 x 0 1 pound 9...

Страница 38: ...able P Print displayed weight stable or unstable CP Continuous Print SP Print displayed stable weight SLP Auto Print stable non zero displayed weight SLZP Auto Print stable non zero weight and stable...

Страница 39: ...s 1 Remote Tare 2 TxD 3 RxD 4 DSR 5 Ground 6 DTR 7 CTS 8 RTS 9 Remote Print 1 2 3 4 5 6 COM 2 MINI DIN Connector TARE PRINT External PRINT and or TARE switches may be installed as shown in the diagram...

Страница 40: ...een damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than Oh...

Страница 41: ...EN 38 Adventurer Pro...

Страница 42: ...Adventurer Pro EN 39...

Страница 43: ...haus Corporation 19A Chapin Road P O Box 2033 Pine Brook NJ 07058 USA Tel 973 377 9000 Fax 973 593 0359 With offices worldwide www ohaus com Ohaus Corporation 2003 all rights reserved P N 12103954 Pri...